Configuring with Web Based Management
4.6 System
SINEMA Remote Connect - Server
52
Operating Instructions, 11/2017, C79000-G8976-C383-04
4.6.2.3
Web server settings
Calling the Web page
In the navigation panel, select "System > Network configuration" and the "Web server
settings" tab.
Box
Meaning
HTTPS port
Specify via which port HTTPS remote access to the WBM will take place.
HTTPS default port 443
Fallback port
Specify the fallback port.
This port is used by OpenVPN devices that update the configurations using the
auto enrollment mechanism (update interval).
If no access is possible for these devices via the HTTPS port, the update takes
place via the fallback port.
Fallback default port 6220
Changing port numbers
If you change port numbers, use ports from the number range 1024 ... 65535.
Select a free port that is not otherwise being used e.g.by the TCP port in OpenVPN.
Ports 0 ... 1023 are standardized (well known ports). From the registered ports as of 1024,
for example no. 1024 is reserved.
If you use another port as the default port 443, the port number along with the IP address
must be entered. A colon ":" must be entered between the IP address and the port number
as a delimiter.
Example:
If SINEMA RC can be reached via the Internet at the IP address 192.144.112.5, and when in
addition to this port number 6443 was specified for remote access, the following information
must be specified for the remote station in the Web browser:
●
https://192.144.112.5:6443
4.6.3
Date and time settings
To check the validity of certificates and for the time stamps of log entries, the current date
and time are kept. You can set the system time yourself manually or have it synchronized
automatically with an NTP server. Only one method can be active at any one time.
Calling the Web page
In the navigation, select "System > Date & time settings".