Required tools
● A suitable, flat cooling water catchment tray with a capacity of at least seven liters for
draining the drive
● Open-ended spanner (16 mm, 18 mm, 22 mm)
● Socket spanner set
Removing a phase module
Prepare the changing deviceas described in Section "Attaching the changing device to the
Preparation
1. Remove the electrical connections from the lifting solenoids
③
.
2. Loosen the screws connecting the central brace with the frame of the cabinet, and remove
the central brace.
Figure 9-14
Lifting solenoid
Maintenance