![Siemens SINAMICS SM150 6SL3815-7NP41-0AA1 Скачать руководство пользователя страница 51](http://html.mh-extra.com/html/siemens/sinamics-sm150-6sl3815-7np41-0aa1/sinamics-sm150-6sl3815-7np41-0aa1_operating-instructions-and-installation-instructions_378234051.webp)
WARNING
High voltages
The drive is not disconnected from the supply system by the "Safe Torque Off / Safe Standstill"
function. Dangerous voltages of over 1000 V are present on the motor and drive.
High voltages can cause death or serious injury if the safety rules are not observed or if the
equipment is handled incorrectly.
● Do not undertake any work on electrical connections without previously putting all the
necessary precautions in place. Observe the five safety rules before undertaking work on
the equipment.
See also
3.6.12.2
Description
The central components of the "Safe Torque Off" function are the safety relay -K110 and the
PSA. Standard components are used for the additionally required time relay -K120 and
auxiliary contactors ‑K121, ‑K125 and ‑K130.
Description
3.6 Description of options
SINAMICS SM150 6SL3815-7NP41-0AA1
Operating Instructions Rev.201910281301 EXAMPLE
51
Содержание SINAMICS SM150 6SL3815-7NP41-0AA1
Страница 2: ...28 10 2019 13 01 V32 00 ...
Страница 116: ...Start up SINAMICS SM150 6SL3815 7NP41 0AA1 116 Operating Instructions Rev 201910281301 EXAMPLE ...
Страница 176: ...Maintenance 9 5 Repair SINAMICS SM150 6SL3815 7NP41 0AA1 176 Operating Instructions Rev 201910281301 EXAMPLE ...
Страница 178: ...Spare parts SINAMICS SM150 6SL3815 7NP41 0AA1 178 Operating Instructions Rev 201910281301 EXAMPLE ...
Страница 182: ...Service Support SINAMICS SM150 6SL3815 7NP41 0AA1 182 Operating Instructions Rev 201910281301 EXAMPLE ...
Страница 193: ......
Страница 196: ......
Страница 198: ......