Distributed system components
● S120M (1FK7 synchronous motor with integrated Power Module encoder)
● Hybrid cable (connection system)
● DRIVE-CLiQ extension (DQE)
3.4.1
Component specification according to UL
The components of the SINAMICS S120M drive system are UL-certified. The certification is
indicated on the products using the UL Listing Mark.
The UL File Number for the SINAMICS S120M drive system is E192450.
Note
UL ratings
When using components in the area of validity of UL ("Underwriters Laboratories Inc.
®
"),
observe the UL ratings below for the individual components. They deviate in some cases from
the general parameters (see documentation of the component in question).
The specifications for rated current/power apply for an ambient temperature of max. +40 °C. If
the components are operating in the range b40 °C and +55 °C, the linear reductions
of the output currents or output powers to 60% should be used.
Note
Connection to line supply systems
S120M components are only suitable for direct connection to line supplies with a grounded
neutral point.
Note
Using the 24 V terminal adapter
When using the 24 V terminal adapter (Page 131) only use wires with a temperature rating of
60/75°C and a cross-section of AWG 10-20 (stranded wires). Alternatively, you can use the
busbars to establish the connection.
Table 3-1
Technical data of the Adapter Module 600 (AM600) according to UL
AM600
Unit
6SL3555-2BC10-0AA.
Max. ambient temperature
°C
40
55 (with derating)
Electronics power supply / (input)
Electronics voltage
Electronics current
V
DC
A
DC
24
20
24
20
Line electronics supply/(output)
Electronics power supply
Output current
V
DC
A
DC
48
10
48
10
System overview
3.4 SINAMICS S120 components
Manual, 06/2019, 6SL3097-5AW00-0BP1
39
Содержание Sinamics S120M
Страница 1: ...Equipment Manual Distributed drive technology Edition www siemens com drives 06 2019 S120M SINAMICS ...
Страница 2: ......
Страница 20: ...Introduction 1 8 General Data Protection Regulation 18 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Страница 32: ...Fundamental safety instructions 2 4 Residual risks of power drive systems 30 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Страница 56: ...System overview 3 5 System Data 54 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Страница 110: ...S120M 5 11 Motor holding brake 108 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Страница 118: ...DRIVE CLiQ Extension 6 6 Technical data 116 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Страница 126: ...Hybrid Cabinet Bushing 7 6 Technical data 124 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Страница 182: ...Appendix A 2 Documentation overview 180 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Страница 185: ......