Now you can remove the S120M.
NOTICE
Damage to the signal cables when replacing the S120M
Signal cables can be damaged when the S120M is disassembled.
● When withdrawing the S120M, ensure that you do not damage any signal cables.
Installation steps
To install the AM600, perform the removal steps in the reverse order.
NOTICE
Equipment damage due to unsuitable tightening torques
Unsuitable tightening torques can cause damage to components.
● Carefully insert the plug connections and ensure that they are secure.
● Attach the hybrid cable using an Allen key and check that the connections are secure.
9.2.4
Replacing a fuse in the Adapter Module 600
Preparatory steps
1. Disconnect the drive line-up.
2. Allow unimpeded access to the Adapter Module 600 (AM600).
3. Check that the cabinet is de-energized.
Service and maintenance
9.2 Replacing components
160
Manual, 06/2019, 6SL3097-5AW00-0BP1
Содержание Sinamics S120M
Страница 1: ...Equipment Manual Distributed drive technology Edition www siemens com drives 06 2019 S120M SINAMICS ...
Страница 2: ......
Страница 20: ...Introduction 1 8 General Data Protection Regulation 18 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Страница 32: ...Fundamental safety instructions 2 4 Residual risks of power drive systems 30 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Страница 56: ...System overview 3 5 System Data 54 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Страница 110: ...S120M 5 11 Motor holding brake 108 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Страница 118: ...DRIVE CLiQ Extension 6 6 Technical data 116 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Страница 126: ...Hybrid Cabinet Bushing 7 6 Technical data 124 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Страница 182: ...Appendix A 2 Documentation overview 180 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Страница 185: ......