Communication
11.6 Communication via SINAMICS Link
Drive functions
Function Manual, 11/2017, 6SL3097-4AB00-0BP5
889
Send and receive data
The SINAMICS Link telegram contains 32 indices (0...31) for the process data (PZD1...32).
Each PZD is precisely 1 word long (= 16 bits). Indices that are not required are automatically
filled with zeros. There is always a fixed assignment between the index and PZD: The index i
corresponds to PZD i+1.
Index
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
PZD
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
SINAMICS Link telegram content, Part 1
Index
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
PZD
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
SINAMICS Link telegram content, Part 2
Each transfer cycle, every SINAMICS Link node can send 1 telegram with 32 PZD. Each
node receives all of the telegrams that are sent. For each transfer cycle clock, a node can
select and process up to 32 PZD from all telegrams that have been received. Single words
and double words can be sent and received. You must write double words in two
consecutive PZDs.
Limitations:
●
In a telegram, a PZD may only be sent and received once. If a PZD occurs more than
once in a telegram, then Alarm A50002 or A50003 is output.
●
It is not possible to read in your own send data. SINAMICS S then initiates the
corresponding alarms. The following alarms are possible:
–
A50006: It is parameterized that own data sent can be received. This is not permitted.
–
A50007: The send telegram word is larger than possible in the project.
–
A50008: The receive telegram word is larger than possible in the project.
●
The maximum number of PZDs that can be received and sent also depends on the drive
object. The number of PZDs that can be evaluated corresponds to communication
according to PROFIdrive; however, for SINAMICS Link, it is limited to a maximum of 32
PZDs.
●
If, as a result of a project download, parameters of the CBE20 are change, then alarm
A08531 is output. In this case, a POWER ON is required to activate the values.
Transmission time
With SINAMICS Link, a transmission time of up to 500 µs is possible (with a max. controller
cycle of 500 µs; synchronous bus cycle of 500 µs).
Содержание SINAMICS S120
Страница 1: ......
Страница 2: ......
Страница 24: ...Contents Drive functions 24 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 202: ...Servo control 4 21 Voltage precontrol Drive functions 202 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 296: ...Vector control 5 23 Asynchronous pulse frequency Drive functions 296 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 312: ...V f control vector control 6 5 Vdc control Drive functions 312 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 932: ......
Страница 1044: ...Appendix A 2 Documentation overview Drive functions 1044 Function Manual 11 2017 6SL3097 4AB00 0BP5 A 2 Documentation overview ...
Страница 1082: ...Appendix A 7 Functions of SINAMICS S120 Combi Drive functions 1082 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 1094: ......