Communication
11.3 Communication via PROFINET IO
Drive functions
Function Manual, 11/2017, 6SL3097-4AB00-0BP5
821
11.3.3
PROFINET GSDML
SINAMICS S120 supports the GSDML version: "PROFINET GSDML" to embed the
converter in a PROFINET network.
PROFINET GSDML allows standard telegrams to be combined with a PROFIsafe telegram –
and if required, a telegram extension. Each of the modules has four subslots: The Module
Access Point (MAP), the PROFIsafe telegram, a PZD telegram to transfer process data and
where necessary, a telegram for PZD extensions. Example:
GSDML-V2.31-Siemens-Sinamics_S_CU3x0_20160101.xml
You can download GSDML files from the following Siemens Internet address:
PROFINET GSDML (
https://support.industry.siemens.com/cs/ww/en/view/49217480
The GSDML files on the memory card are saved in the following location:
..\SIEMENS\SINAMICS\DATA\CFG\PNGSD.ZIP
The following table shows the possible submodules depending on the particular drive object.
Table 11- 14 Submodules depending on the particular drive object
Module
Sub-
slot 1
MAP
Subslot 2
PROFIsafe
Subslot 3
PZD telegram
Subslot 4
PZD extension
Subslot 5
Max.
number
of PZD
SERVO
MAP
Telegram
30/31/901/902/903
Telegrams: 1...220
free PZD-16/16
Supplementary
telegrams
700/701/750, PZD-
2/2, -2/4, -2/6, -8/8
Supplementary
telegrams
700/701/750, PZD-
2/2, -2/4, -2/6, -8/8
20/28
VECTOR
MAP
Telegram
30/31/901/902/903
Telegrams: 1...352
free PZD-16/16,
32/32
Supplementary
telegrams
700/701/750, PZD-
2/2, -2/4, -2/6, -8/8
Supplementary
telegrams
700/701/750, PZD-
2/2, -2/4, -2/6, -8/8
32/32
Infeed
MAP
Reserved
Telegrams: 370,
371
free PZD-4/4
PZD-2/2, -2/4, -2/6 Reserved
10/10
Encoder
MAP
Reserved
Telegrams: 81, 82,
83
free PZD-4/4
PZD-2/2, -2/4, -2/6 Reserved
4/12
TB30, TM31,
TM15 DI_DO,
TM120
MAP
Reserved
Telegrams: no
free PZD-4/4
Reserved
Reserved
5/5
TM150
MAP
Reserved
Telegrams: no
free PZD-4/4
Reserved
Reserved
7/7
TM41
MAP
Reserved
Telegrams: 3
free PZD-4/4, 16/16
Reserved
Reserved
20/28
Control Unit
MAP
Reserved
Telegrams: 390,
391, 392, 393, 394,
395
free PZD-4/4
Reserved
Reserved
5/21
TM15/TM17
Not supported.
The telegrams in subslots 2, 3 and 4 can be freely configured, i.e. they can also remain empty.
Содержание SINAMICS S120
Страница 1: ......
Страница 2: ......
Страница 24: ...Contents Drive functions 24 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 202: ...Servo control 4 21 Voltage precontrol Drive functions 202 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 296: ...Vector control 5 23 Asynchronous pulse frequency Drive functions 296 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 312: ...V f control vector control 6 5 Vdc control Drive functions 312 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 932: ......
Страница 1044: ...Appendix A 2 Documentation overview Drive functions 1044 Function Manual 11 2017 6SL3097 4AB00 0BP5 A 2 Documentation overview ...
Страница 1082: ...Appendix A 7 Functions of SINAMICS S120 Combi Drive functions 1082 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 1094: ......