Communication
11.1 Communication according to PROFIdrive
Drive functions
Function Manual, 11/2017, 6SL3097-4AB00-0BP5
767
11.1.5.1
PROFINET-based diagnostics
For PROFINET, to transfer PROFIdrive message classes, channel diagnostics (Channel
Diagnosis) are used (see PROFINET IO specification (
A message always comprises the following components in this specific sequence:
●
Block Header (6 Byte)
–
Blocktype
–
Blocklength
–
BlockversionHigh
–
BlockversionLow
●
API (4 Byte)
●
Slot Number (2 Byte)
●
Sub Slot Number (2 Byte)
●
Channel Number (2 Byte)
●
Channel Properties (0x8000) (2 Byte)
●
User Structure Identifier (2 Byte)
●
Channel Diagnosis Data (6 Byte)
–
Channel Number (2 Byte)
–
Channel Properties (2 Byte)
–
Channel Error Type (2 Byte)
Overview:
Figure 11-10 Components of a message