Monitoring functions and protective functions
9.5 Thermal motor protection
Drive functions
Function Manual, 11/2017, 6SL3097-4AB00-0BP5
655
Bimetallic NC contact
●
p4100[0...3] = 4 sets the temperature sensor type bimetal NC contact, and activates the
evaluation.
●
r4105[0...3] displays the actual temperature value of the temperature evaluation.
–
If the actual temperature value is lower than the rated response temperature, then
r4105[0...3] is set to -50° C.
–
If the actual temperature value is higher than the rated response temperature, then
r4105[0...3] is set to 250° C.
–
If no sensor has been selected or if the actual temperature value is invalid, then
r4105[0...3] is set to -300° C.
9.5.7
Terminal Module 150
The Terminal Module 150 (TM150) has 6x 4-pole terminals for temperature sensors.
Temperature sensors can be connected in a 1x2, 1x3 or 1x4-wire system. In a 2x2-wire
system, up to 12 input channels can be evaluated. 12 input channels can be evaluated in the
factory setting. The temperature channels of a TM150 can be subdivided into three groups
and evaluated together.
The TM150 can acquire the signals from KTY84, PTC, bimetallic NC contact, PT100 and
PT1000 temperature sensors and evaluate them. The fault and/or alarm thresholds of the
temperature values can be set from -99° C up to 251° C. The temperature sensors are
connected at terminal strip X531 to X536 according to the following table.
The TM150 temperature inputs are not isolated.
Note
Fault messages
Fault messages for an individual temperature channel in the TM150 are propagated to all
other drive objects connected with the TM150.
As such all other drive objects (connected with the TM150) also trigger a fault.
You can find additional information in the function diagrams 9625, 9626 and 9627 in the
SINAMICS S120/S150 List Manual.
Содержание SINAMICS S120
Страница 1: ......
Страница 2: ......
Страница 24: ...Contents Drive functions 24 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 202: ...Servo control 4 21 Voltage precontrol Drive functions 202 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 296: ...Vector control 5 23 Asynchronous pulse frequency Drive functions 296 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 312: ...V f control vector control 6 5 Vdc control Drive functions 312 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 932: ......
Страница 1044: ...Appendix A 2 Documentation overview Drive functions 1044 Function Manual 11 2017 6SL3097 4AB00 0BP5 A 2 Documentation overview ...
Страница 1082: ...Appendix A 7 Functions of SINAMICS S120 Combi Drive functions 1082 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 1094: ......