![Siemens SINAMICS S120 Скачать руководство пользователя страница 396](http://html.mh-extra.com/html/siemens/sinamics-s120/sinamics-s120_function-manual_376543396.webp)
Basic functions
7.23 Creating an encoder as drive object
Drive functions
396
Function Manual, 11/2017, 6SL3097-4AB00-0BP5
7.23
Creating an encoder as drive object
Encoders can be linked in as autonomous drive objects (Drive Object =DO) and evaluated.
An ENCODER drive object can be addressed as encoder via PROFIBUS/PROFINET as an
independent unit.
Using an ENCODER drive object allows an encoder of an upstream machine to be directly
connected via a Sensor Module without having to take an indirect route via the 2nd encoder
of a drive. The encoder is connected via an encoder interface of a Sensor Modules. If the
Sensor Modules, to which the encoder is connected, has its own DRIVE-CLiQ interface (e.g.
an SME20), then the encoder can be connected to any free DRIVE-CLiQ socket via the
Sensor Module.
7.23.1
Requirements for creating a project
Requirements
●
As of STARTER V4.1.5
●
Project with one CU320-2
The project can also be created OFFLINE. A description of this can be found in Section
"Commissioning" in the SINAMICS S120 Commissioning Manual with STARTER.
Connection conditions for ENCODER drive objects
●
All encoders that can be assigned to a drive can be used.
●
ENCODER drive objects may be connected to all DRIVE-CLiQ ports.
●
Up to 4 DRIVE-CLiQ HUBs (DMC20 or DME20) can be used to establish a star-shaped
wiring of the ENCODER drive objects. This means that a maximum of 19 possible
ENCODER drive objects can be connected to one Control Unit.
(This means that the number of possible ENCODER drive objects is restricted so that a
maximum of 24 drive objects can be connected to one Control Unit.)
●
The DRIVE-CLiQ HUBs must be directly connected to the Control Unit.
Содержание SINAMICS S120
Страница 1: ......
Страница 2: ......
Страница 24: ...Contents Drive functions 24 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 202: ...Servo control 4 21 Voltage precontrol Drive functions 202 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 296: ...Vector control 5 23 Asynchronous pulse frequency Drive functions 296 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 312: ...V f control vector control 6 5 Vdc control Drive functions 312 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 932: ......
Страница 1044: ...Appendix A 2 Documentation overview Drive functions 1044 Function Manual 11 2017 6SL3097 4AB00 0BP5 A 2 Documentation overview ...
Страница 1082: ...Appendix A 7 Functions of SINAMICS S120 Combi Drive functions 1082 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 1094: ......