Basic functions
7.21 Parking axis and parking encoder
Drive functions
Function Manual, 11/2017, 6SL3097-4AB00-0BP5
387
7.21
Parking axis and parking encoder
The "parking" function is used in two ways:
●
"Parking axis"
–
Monitoring of all encoders and Motor Modules assigned to the "Motor control"
application of a drive are suppressed.
–
All encoders assigned to the "Motor control" application of a drive are prepared for the
"removed" state.
–
The Motor Module assigned to the "Motor control" application of a drive is prepared for
the "removed Motor Module" state.
●
"Parking encoder"
–
Monitoring of a certain encoder is suppressed.
–
The encoder is prepared for the "removed" state.
Parking an axis
When an axis is parked, the power unit and all the encoders assigned to the "motor control"
are switched to inactive (r0146[n] = 0).
●
Control is carried out via the control/status words of the cyclic telegram (STW2.7 and
ZSW2.7) or using parameters p0897 and r0896.0.
●
The drive must be brought to a standstill by the higher-level controller (disable pulses,
e.g. via STW1.0/OFF1).
●
DRIVE-CLiQ communication to downstream components via the deactivated power unit
(r0126 = 0) remains active.
●
A measuring system that is not assigned to the "motor control" (e.g. direct measuring
system) remains active (r0146[n] = 1).
●
The drive object remains active (r0106 = 1).
Note
Once the "Parking axis" / "Parking encoder" status has been canceled, you may have to
carry out the following actions:
•
If the motor encoder has been replaced: determine the commutation angle offset (p1990).
•
A new encoder must be referenced again (e.g. to determine the machine zero point).
Содержание SINAMICS S120
Страница 1: ......
Страница 2: ......
Страница 24: ...Contents Drive functions 24 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 202: ...Servo control 4 21 Voltage precontrol Drive functions 202 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 296: ...Vector control 5 23 Asynchronous pulse frequency Drive functions 296 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 312: ...V f control vector control 6 5 Vdc control Drive functions 312 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 932: ......
Страница 1044: ...Appendix A 2 Documentation overview Drive functions 1044 Function Manual 11 2017 6SL3097 4AB00 0BP5 A 2 Documentation overview ...
Страница 1082: ...Appendix A 7 Functions of SINAMICS S120 Combi Drive functions 1082 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Страница 1094: ......