Description of the motor
1.5 Selection and ordering data
1PM6/1PM4 Hollow-Shaft Motors for Main Spindle Drives
Configuration Manual, PPMS, 04/2008, 6SN1197-0AD23-0BP0
19
1.5
Selection and ordering data
1)
For continuous duty (with 30%
n
max
, 60%
2
/
3
n
max
, 10% standstill) for
a duty cycle time of 10 min. For maintenance intervals for motors and
components, see 1PM Motors Configuration Manual.
2)
Star/delta changeover.
3)
With option L37: Version for increased maximum speed.
4)
Only star connection possible.
5)
For 1PM6101 and 1PM6105 only.
6)
Version for increased maximum speeds includes vibration magnitude
grade SR. The following options are not possible:
•
ZF gearbox mounting prepared
•
Shaft seal.
Shaft
height
Rated
speed
Contin-
uous
speed,
max.
Speed,
max.
1)
Rated power for
star
n
ratedY
= 1500 rpm
Rated power for
delta
n
rated
Δ
= 4000 rpm
1PM4 asynchronous motor
with hollow shaft
1PM6 asynchronous motor
with hollow shaft
SH
star
delta
n
S1cont
n
max
P
rated
P
rated
S1
S6-40%
S1
S6-40%
Order No.
Standard type
Order No.
Standard type
rpm
rpm
rpm
rpm
kW
(HP)
kW
(HP)
kW
(HP)
kW
(HP)
Oil cooling
2)
Forced ventilation
100
1500
1500
1500
1500
4000
4000
4000
4000
12000
18000
12000
18000
12000
18000
12000
18000
3.7 (4.96)
3.7 (4.96)
7.5 (10.1)
7.5 (10.1)
5.25 (7.04)
5.25 (7.04)
11 (14.8)
11 (14.8)
3.7 (4.96)
3.7 (4.96)
7.5 (10.1)
7.5 (10.1)
6 (8.05)
6 (8.05)
13 (17.4)
13 (17.4)
1PM4101 - 2
7
F86 - 1
7
S1
1PM4101 - 2L F86 - 1
7
S1
3)
1PM4105 - 2
7
F86 - 1
7
S1
1PM4105 - 2L F86 - 1
7
S1
3)
1PM6101 - 2
7
F8
7
- 1
7 7
1
1PM6101 - 2L F8
7
- 1
7 7
1
3)
1PM6105 - 2
7
F8
7
- 1
7 7
1
1PM6105 - 2L F8
7
- 1
7 7
1
3)
132
1500
1500
1500
1500
1500
1500
4000
4000
4000
4000
4000
4000
10000
15000
10000
12000
10000
11000
10500
15000
10500
12000
10500
11000
11 (14.8)
11 (14.8)
18.5 (24.8)
18.5 (24.8)
22 (29.5)
22 (29.5)
16.5 (22.1)
16.5 (22.1)
28 (37.5)
28 (37.5)
33 (44.3)
33 (44.3)
11 (14.8)
11 (14.8)
18.5 (24.8)
18.5 (24.8)
22 (29.5)
22 (29.5)
19.5 (26.1)
19.5 (26.1)
32 (42.9)
32 (42.9)
39 (52.3)
39 (52.3)
1PM4133 - 2
7
F86 - 1
7
S1
1PM4133 - 2L F86 - 1
7
S1
3)
1PM4137 - 2
7
F86 - 1
7
S1
1PM4137 - 2L F86 - 1
7
S1
3)
–
–
1PM6133 - 2
7
F8
7
- 1
7 7
1
1PM6133 - 2L F8
7
- 1
7 7
1
3)
1PM6137 - 2
7
F8
7
- 1
7 7
1
1PM6137 - 2L F8
7
- 1
7 7
1
3)
1PM6138 - 2
7
F8
7
- 1
7 7
1
1PM6138 - 2L F8
7
- 1
7 7
1
3)
Water cooling
4)
100
1500
1500
1500
1500
12000
18000
12000
18000
12000
18000
12000
18000
5 (6.71)
5 (6.71)
11 (14.8)
11 (14.8)
6.5 (8.72)
6.5 (8.72)
14.75 (19.8)
14.75 (19.8)
–
–
–
–
–
–
–
–
1PM4101 - 2
7
W26 - 1
7
S1
1PM4101 - 2
7
W26 - 1
7
S1
3)
1PM4105 - 2
7
W26 - 1
7
S1
1PM4105 - 2
7
W26 - 1
7
S1
3)
132
1500
1500
1500
1500
10000
15000
10000
12000
10500
15000
10500
12000
15 (20.1)
15 (20.1)
27 (36.2)
27 (28.2)
21 (28.2)
21 (28.2)
38 (51.0)
38 (51.0)
–
–
–
–
–
–
–
–
1PM4133 - 2
7
W26 - 1
7
S1
1PM4133 - 2
7
W26 - 1
7
S1
3)
1PM4137 - 2
7
W26 - 1
7
S1
1PM4137 - 2
7
W26 - 1
7
S1
3)
Encoder system for motors
without DRIVE-CLiQ interface:
Incremental encoder sin/cos 1 V
pp
, 256 S/R
Encoder system for motors
with DRIVE-CLiQ interface:
Incremental encoder 19 bit (Encoder IN19DQ)
L
L
V
V
L
V
Type:
IM B35, IM V15, IM V35
IM B5
IM V1
IM V3
1
4
5
Fans:
Without fan combined
with terminal box/metric
cable entry
Top/right
Top/DE
Top/NDE
Top/left
Axial fan/Blow-out direction below/Direction of air flow DE
→
NDE
combined with terminal box/metric cable entry
Top/right
Top/DE
Top/NDE
Top/left
Radial fan/Blow-out direction NDE/Direction of air flow DE
→
NDE
combined with terminal box/metric cable entry
Right side/below
Right side/DE
Right side/NDE
5)
A
B
C
D
A
B
C
D
R
R
R
R
E
F
G
D
D
D
(Encoder IN256S/R)