CANope
n inter
face
Fu
nction dia
g
ra
ms
2-
95
7
© Siemens AG 2
012 All Rights Reserved
SINAMICS
S110 List Manual (L
H7)
, 06/
2012
, 6SL3097-
4AP10-0BP3
Fi
g.
2
-1
83
920
6 – Receive
tele
gram,
Pred
efined
Co
nne
ctio
n Set (p8
744 =
1)
- 9206 -
Function diagram
8
7
6
5
4
3
2
1
fp_9206_98_eng.vsd
DO: SERVO
SINAMICS S110
04.11.09 V04.04.00
CANopen interface - Receive telegram, Predefined Connection Set (p8744 = 1)
X126
CAN bus
r2060[4]
DWORD
Bit 0
r2091.0
r2050[1]
Bit 15
r2091.15
Bit 0
r2090.0
r2050[0]
Bit 15
r2090.15
...
r2060[2]
DWORD
Bit 0
r2093.0
r2050[3]
Bit 15
r2093.15
Bit 0
r2092.0
r2050[2]
Bit 15
r2092.15
...
...
r2060[1]
DWORD
...
r2050[5]
r2050[4]
r2060[5]
DWORD
r2050[6]
r2060[3]
DWORD
r2060[6]
DWORD
r2050[7]
r2060[7]
DWORD
r2050[8]
r2060[8]
DWORD
r2050[9]
r2060[9]
DWORD
r2050[10]
r2060[10]
DWORD
r2050[11]
r2060[11]
DWORD
r2050[12]
r2060[12]
DWORD
r2050[13]
r2060[13]
DWORD
r2050[14]
r2060[14]
DWORD
r2050[15]
CANopen
receive telegram
Object 4
COB-ID
Object 1
r2060[0]
DWORD
PZD receive word 1
PZD receive word 2
PZD receive word 5
PZD receive word 3
PZD receive word 4
PZD receive word 6
PZD receive word 7
PZD receive word 8
PZD receive word 9
PZD receive word 10
PZD receive word 11
PZD receive word 12
PZD receive word 13
PZD receive word 14
PZD receive word 15
PZD receive word 16
Evaluation
of the
COB-ID
COB-ID for RPDO 1
p8700[0]
PDO mapping for RPDO 1
p8710[0...3]
60400010
60400010
60FF0020
p8703[0]
60400010
60FF0020
60710010
The assignment is
made from RPDO
1, RPDO 2 ...
RPDO 4 and from
receiver word 1.
Objects available a
multiple number of
times are
marshalled to the
same position in the
receive buffer.
Automatic assignment of the
RPDOs to the receive buffer
Receive buffer
p8713[0...3]
p8702[0]
60400010
60710010
p8712[0...3]
p8701[0]
p8711[0...3]
RPDO 1
RPDO 2
RPDO 3
RPDO 4
<2>
Refer to [1020.7]
CAN bus sampling time
<1>
RPDO: Receive Process Data Object
COB-ID: CAN Communication Object Identifier
r2060[15]
DWORD
r2050[16]
r2060[16]
DWORD
r2050[17]
PZD receive word 17
PZD receive word 18
<2> Telegram: up to 4 words or 64 bits. The sum of the various objects must not exceed 18 words.
<1> To use automatic BICO interconnection (p8790 = 1), one of the receive words 1-4 must be used as control word 1 (STW1).