F
u
nct
ion
d
ia
gr
am
s
En
co
de
r ev
alu
a
tion
2-
88
8
© Siemens AG
2012 All Rights Reserved
SINAMICS
S110
List Manual (LH7
), 06/201
2, 6SL3097-
4AP
1
0-0BP3
Fi
g.
2
-1
22
472
0 – En
code
r in
terface,
receive
sig
nals,
encod
ers 1
...
2
- 4720 -
Function diagram
8
7
6
5
4
3
2
1
fp_4720_98_eng.vsd
DO: SERVO
SINAMICS S110
16.07.09 V04.04.00
Encoder evaluation - Encoder interface, receive signals, encoders 1 ... 2
Bits 0...13 control what is transferred
in Gn_XIST 2.
There are 3 alternatives:
- Bit 7 = 0: Position actual value at
the reference mark <2>
- Bit 7 = 1: Position actual value when
the measuring probe
edge is received <2>
- Bit 13 = 1: Cyclic absolute position
value from absolute
encoder
(0)0
p0480[n-1]
Selects the function to be activated (with bit value = 1)
Start/stop/read selected function
0
r0487[n-1]
Enc Gn_STW
Select function 1 [Bit 3...0]
("search for reference mark 1")
Start function [Bit 6...4]
Function active [Gn_ZSW Bit 0]
Actual value save at the
reference mark
Read generated value [Bit 6...4]
Value from function 1 available
[Gn_ZSW Bit 4]
Position actual value at reference
mark 1 in Gn_XIST2
000
000
001
000
010
0001
1
0
1
0
0
0
0
1
0
0
0
1
2
3
4
3
2
1
Function No.
Bit No.
Function for bit 7 = 0
(search for reference mark)
Function for bit 7 = 1
(flying measurement)
Reference mark 1
Measuring probe 1
Reference mark 2
Measuring probe 1
Reference mark 3
Measuring probe 2
Reference mark 4
Measuring probe 2
<1>
Control word for encoder n (n = 1 or 2)
5
7
8...12
13
14
15
Mode of the function to be activated
1 = flying measurement
0 = Search for reference mark (zero mark or BERO)
Reserved part
1 = Request cyclic transfer of the absolute position value in
Gn_XIST2
(e.g. EQN absolute track; acknowledgment in Gn_ZSW bit 13)
1 = Request parking encoder (handshake with Gn_ZSW bit 14)
= acknowledge encoder fault (located in Gn_ZSW, bit 15;
Handshake with Gn_ZSW bit 11)
1
<3>
The bits are processed with the following priority sequence (highest priority -->
lowest priority bit): Bit 14 --> Bit 15 --> Bit 4-7 --> Bit 12 --> Bit 13.
<3>
To the position sensing, encoder n
[4704.3]
6
<4>
The checkback signal is provided in Gn_ZSW bit 14, but the encoder is not
actually parked.
<4>
<1>
PROFIdrive bit
Interrupt function
Read generated value
Activate selected function
No function
4
Refer to [1020.7]
PROFIdrive sampling time
If the "position module" function module (r0108.3 = 1) is activated, the
interconnection is established via r2520[0]...[2] from [4010.8].
If a standard telegram (PROFIdrive) is selected, the interconnection is performed
according to the specifications of the standard telegrams [2420].
<5>
<5>
NOTE: SINAMICS S110 supports only one encoder. This encoder may be parameterized as encoder 1 or encoder 2.
Index [n-1] --> encoder n
Index [0] --> encoder 1
Index [1] --> encoder 2
<1>
Actual position values are read out from Gn.XIST2 using a handshake procedure.
e.g.: Read position value(s) at reference mark(s)
1. Set r0487.[0-2] according to the function to be activated.
2. Set r0487.4 (activate function)
3. Reset all bits from r0487.[0-2] to 0.
4. r0481[0-2] must be active depending on the activated function.
5. Overtravel zero mark(s) until all bits in r0481.[0-2] are reset to 0.
6. Select r0487.[0-2] individually and activate with r0487.5 until r0481.[4-7] is equal
to 1 and read out the position values in r0483.
7. Reset all bits, starting with r0487.5 followed by r0487.[0-2].
<2>
Содержание SINAMICS S110
Страница 1: ...s SINAMICS S110 List Manual 06 2012 SINAMICS ...
Страница 2: ......
Страница 1272: ...List of abbreviations B 1272 Siemens AG 2012 All Rights Reserved SINAMICS S110 List Manual LH7 06 2012 6SL3097 4AP10 0BP3 ...
Страница 1286: ...Index C 1286 Siemens AG 2012 All Rights Reserved SINAMICS S110 List Manual LH7 06 2012 6SL3097 4AP10 0BP3 ...
Страница 1287: ......