F
u
nct
ion
d
ia
gr
am
s
Se
tp
oin
t ch
an
ne
l
2-
85
4
© Siemens AG
2012 All Rights Reserved
SINAMICS
S110
List Manual (LH7
), 06/201
2, 6SL3097-
4AP
1
0-0BP3
Fi
g.
2
-9
2
301
0 – Fixe
d
sp
eed setpo
ints
- 3010 -
Function diagram
8
7
6
5
4
3
2
1
fp_3010_98_eng.vsd
DO: SERVO
SINAMICS S110
30.09.11 V04.04.00
Setpoint channel - Fixed speed setpoints
r1024
Fixed speed setpoint, actual
0 0 1 1
0 1 0 1
0 1 1 0
0 1 1 1
1 0 0 1
1 0 1 0
1 0 1 1
1 1 0 0
1 1 0 1
1 1 1 0
1 1 1 1
0 0 0 1
0 0 1 0
Fixed speed setpoint 1
-210 000.000...210 000.000 [rpm]
p1001[D] (0.000)
Fixed speed setpoint 2
-210 000.000...210 000.000 [rpm]
p1002[D] (0.000)
Fixed speed setpoint 3
-210 000.000...210 000.000 [rpm]
p1003[D] (0.000)
Fixed speed setpoint 4
-210 000.000...210 000.000 [rpm]
p1004[D] (0.000)
Fixed speed setpoint 5
-210 000.000...210 000.000 [rpm]
p1005[D] (0.000)
Fixed speed setpoint 6
-210 000.000...210 000.000 [rpm]
p1006[D] (0.000)
Fixed speed setpoint 7
-210 000.000...210 000.000 [rpm]
p1007[D] (0.000)
Fixed speed setpoint 8
-210 000.000...210 000.000 [rpm]
p1008[D] (0.000)
Fixed speed setpoint 9
-210 000.000...210 000.000 [rpm]
p1009[D] (0.000)
Fixed speed setpoint 10
-210 000.000...210 000.000 [rpm]
p1010[D] (0.000)
Fixed speed setpoint 11
-210 000.000...210 000.000 [rpm]
p1011[D] (0.000)
Fixed speed setpoint 12
-210 000.000...210 000.000 [rpm]
p1012[D] (0.000)
Fixed speed setpoint 13
-210 000.000...210 000.000 [rpm]
p1013[D] (0.000)
Fixed speed setpoint 14
-210 000.000...210 000.000 [rpm]
p1014[D] (0.000)
Fixed speed setpoint 15
-210 000.000...210 000.000 [rpm]
p1015[D] (0.000)
p1001[D]
p1003[D]
p1002[D]
p1004[D]
p1005[D]
p1006[D]
p1007[D]
p1008[D]
p1009[D]
p1010[D]
p1011[D]
p1012[D]
p1013[D]
p1014[D]
0.000
Fixed speed setpoint number actual
0...15
r1197
<100>
Fixed speed setpoint selection bit 0
r1198.0
Fixed speed setpoint selection bit 1
r1198.1
Fixed speed setpoint selection bit 2
r1198.2
Fixed speed setpoint selection bit 3
r1198.3
From
control word
setpoint
channel
0 0 0 0
0 1 0 0
1 0 0 0
[2505.3]
p1020
[2505.3]
p1021
[2505.3]
p1022
[2505.3]
p1023
Refer to [1020.7]
4000.00 μs
<100> For SERVO, the following applies:
Only if the function module "extended setpoint
channel" is activated (r0108.8 = 1).