F
u
nct
ion
d
ia
gr
am
s
PR
OFIdriv
e
2-
81
2
© Siemens AG
2012 All Rights Reserved
SINAMICS
S110
List Manual (LH7
), 06/201
2, 6SL3097-
4AP
1
0-0BP3
Fi
g.
2
-5
5
249
8 – E_
DI
GITAL in
te
rco
nnectio
n
- 2498 -
Function diagram
8
7
6
5
4
3
2
1
fp_2498_98_eng.vsd
DO: CU_S110
SINAMICS S110
18.10.10 V04.04.00
PROFIdrive - E_DIGITAL interconnection
Signal targets for E_DIGITAL
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Inverted
[Function diagram]
signal target
-
-
-
-
-
-
-
E_DIGITAL.1
E_DIGITAL.2
E_DIGITAL.3
E_DIGITAL.4
E_DIGITAL.5
E_DIGITAL.6
E_DIGITAL.8
E_DIGITAL.9
E_DIGITAL.11
E_DIGITAL.12
E_DIGITAL.13
E_DIGITAL.14
E_DIGITAL.15
E_DIGITAL.7
E_DIGITAL.10
E_DIGITAL.0
Signal
<3> Pre-assignment, can be freely changed.
Reserved
Reserved
Digital input 2 (DI 2)
Reserved
Reserved
Reserved
Digital input 11 (DI/DO 11)
Digital input 10 (DI/DO 10)
Digital input 9 (DI/DO 9)
Digital input 1 (DI 1)
Digital input 3 (DI 3)
Reserved
Reserved
Reserved
Digital input 8 (DI/DO 8)
Meaning
Digital input 0 (DI 0)
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
[Function diagram]
Internal status word
-
<3>
Interconnection
parameters
p2082[0] = r0722.8
p2082[3] = r0722.11
-
-
-
p2082[8] = r0722.0
p2082[2] = r0722.10
-
p2082[1] = r0722.9
p2082[9] = r0722.1
p2082[11] = r0722.3
-
-
-
p2082[10] = r0722.2
-
<2>
<2>
<2>
<2>
<2> Can be set via p0728 as input (DI) or output (DO).
<1> Used in telegrams 390, 391, 392, 393 and 394.
<1>
Refer to [1020.7]
PROFIdrive sampling time