Basic positioner
(EPOS)
F
u
nct
ion
D
iag
ra
m
s
2
-12
47
© Siemens AG 2
007 All Rights Reserved
SINAMICS
S List Manual (LH1
), 07/200
7
Fi
gure 2-1
3
2
3
630 – T
ra
v
ersing
ran
ge limits (r0
108.4 =
1)
- 3630 -
Function diagram
8
7
6
5
4
3
2
1
fp_3630_01_eng.vsd
DO: SERVO, VECTOR
SINAMICS S
07.05.07 V02.05.00
EPOS - Traversing range limits (r0108.4 = 1)
Motion variables
Deceleration override
Mode
manager
[3625]
-a_Max
1...2000000 [1000 LU/s2]
p2573 (100)
Acceleration override
a_Max
1...2000000 [1000 LU/s2]
p2572 (100)
Velocity
r2669
Op mode act
p0115[5]
v_Max
1...40000000 [1000 LU/min]
p2571 (30000)
0
r2681
Position
SW limit switch PLUS
-2147483648...2147483647 [LU]
p2581 (2147483647)
p2581
SW limSwPlus src
(p2581)
p2579
SW limSwitch minus
-2147483648...2147483647 [LU]
p2580 (-2147483647)
p2580
SW limSw min src
(p2580)
p2578
1 = Reference point set
r2684.11
[3635.4]
1
v_over
(1)
p2646
-a [3635.1]
<1>
<1> When the “reference point approach“ mode is active, the velocity override influences the approach velocity reference cams (p2605).
However, the approach velocity reference zero mark (p2608) and the approach velocity reference point (p2611) are not influenced.
<2> The STOP cams are low active.
When a cam responds, the drive brakes with maximum deceleration along the ramp. After the fault has been acknowledged, only
movements away from the STOP cam are permitted.
&
&
A07477
"Target position < software limit switch minus"
F07475
"Target position < start of traversing range"
A07478
"Target position > software limit switch plus"
F07476
"Target position > end of traversing range"
<2>
<2>
<2>
STOP cam minus active
r2684.13
STOP cam plus active
r2684.14
A07457
A07486
A07487
F07490
F07491
F07492
1
0
Motion variables of the
"Jog" mode
"Reference point approach"
"Traversing blocks"
"Direct setpoint input/MDI"
Initial state
v = 0, a = 100 %, -a = 100 %
[3610.8]
[3612.8]
[3616.8]
[3620.8]
v [3635.1]
a [3635.1]
[3646.7]
End of traversing range
Start of traversing range
1
0
s [3635.1]
p2568
(0)
STOP cam act
p2569
(1)
STOP cam minus
p2570
(1)
STOP cam plus
p2582
(0)
SW lim sw act
[3646.3]
[3646.3]
A07456 “Setpoint velocity limited“
Velocity limiting active
r2683.1
[3645.3]
0-200 %
[3625]
p2577
(0)
Modulo corr act
[3646.3]
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...