
Menu
8.7 Extras Menu
Intelligent Operating Panel 2 (IOP-2)
Operating Instructions, 06/2020, FW V2.6, A5E39549448B AH
65
5.
Disconnect the IOP-2 from the PC.
6.
Connect another IOP-2 and copy the saved parameter sets to the "user/cps" on the new IOP-
2.
This procedure can be repeated for any number of IOP-2s.
8.7
Extras Menu
Overview
The Extras menu presents a number of options for the
configuration of the IOP-2, these are explained in this
section.
Drive identity
This option allows the user to display the technical details of
the components that comprise the converter system. This
includes the details of the Control Unit and Power Module.
This is a read-only screen and cannot be modified.
Parameter settings
Drive factory reset
There are two factory reset options:
Factory reset
- This option reset all parameters to their
factory default settings. Any safety parameters that have
been modified will not be reset.
Safety factory reset
- This option resets all the safety
parameters back to the factory default settings. No other
parameters will be changed.