S
IN
A
MICS
G1
30/G150
List
Manual (LH
2)
, 07/2
016
, A5E0326347
9A
12
99
3
F
un
ction dia
g
ra
ms
3.
20
Diagn
ostics
F
ig.
3
-178
80
65 – Alarm
b
uffe
r
- 8065 -
Function diagram
8
7
6
5
4
3
2
1
fp_8065_51_eng.vsd
DO: All objects
SINAMICS
25.02.14 V04.08.00
Diagnostics - Alarm buffer
Alarm value
Alarm time
"come"
Alarm time
"removed"
Alarm code
RESET
Alarm comes
Alarms
counter
p2111
p2111 = 0:
Alarm buffer is deleted
1
Delete alarm buffer
r2122 = 0
r2123 = 0
r2124 = 0
r2125 = 0
r2134 = 0
r2145 = 0
r2146 = 0
r3121 = 0
r3123 = 0
Alarm goes
Alarm comes
1
Counter
16 bit
III
RESET
III
RESET
Fault buffer change [8060.8]
III
RESET
1
Fault/alarm buffer
changes from
other drive objects
POWER ON
16 bit counter,
free running
16 bit counter,
free running
Alarm number
r2110
Operating time
Alarm times
Alarm buffer
change
POWER ON
r2132
Actual alarm code
0 = "No alarm present"
External alarm 1
r2138.10
External alarm 2
r2138.11
External alarm 3
r2138.12
Background
[2546.3]
p2112
[2546.3]
p2116
[2546.3]
p2117
r2122[0]
r2122[1]
r2122[7]
r2124[0] [I32]
r2134[0] [Float]
r2124[1] [I32]
r2134[1] [Float]
r2124[7] [I32]
r2134[7] [Float]
r2123[0] [ms]
r2145[0] [d]
r2123[1] [ms]
r2145[1] [d]
r2123[7] [ms]
r2145[7] [d]
r2125[0] [ms]
r2146[0] [d]
r2125[1] [ms]
r2146[1] [d]
r2125[7] [ms]
r2146[7] [d]
[8060.1]
Alarm 1
(oldest)
Alarm 2
Alarm 8
(most recent)
POWER ON
r2122[8]
r2122[9]
r2122[63]
r2124[8] [I32]
r2134[8] [Float]
r2124[9] [I32]
r2134[9] [Float]
r2124[63] [I32]
r2134[63] [Float]
r2123[8] [ms]
r2145[8] [d]
r2123[9] [ms]
r2145[9] [d]
r2123[63] [ms]
r2145[63] [d]
r2125[8] [ms]
r2146[8] [d]
r2125[9] [ms]
r2146[9] [d]
r2125[63] [ms]
r2146[63] [d]
Alarm 1
(most recent)
Alarm 2
Alarm 56
(oldest)
Alarm history
<1> The buffer parameters are updated cyclically in the background (see status signal in r2139).
<1>
Control Unit Warning Present
r3114.9
r3121[63]
r3121[9]
r3121[8]
r3121[7]
r3121[1]
r3121[0]
Component
number
alarm
r3123[63]
r3123[9]
r3123[8]
r3123[7]
r3123[1]
r3123[0]
Diagnostic
attribute
alarm
r2121
Alarm buffer change
r2120
Alarm buffer change
[2548.2]
Alarm present
r2139.7
Alarm class bit 1
r2139.12
Maintenance required
r2139.13
Maintenance urgently required
r2139.14
Alarm class bit 0
r2139.11
r2139
ZSW fault/alarm 1
Alarm present
r0196.8
Alarm class bit 1
r0196.12
Maintenance required
r0196.13
Maintenance urgently required
r0196.14
Alarm class bit 0
r0196.11
r0196[0...255]
Top comp stat
Содержание SINAMICS G130
Страница 1: ...s SINAMICS SINAMICS G130 G150 List Manual 07 2016 Edition ...
Страница 2: ......
Страница 8: ...Preface SINAMICS G130 G150 8 List Manual LH2 07 2016 A5E03263479A ...
Страница 1940: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS G130 G150 1940 List Manual LH2 07 2016 A5E03263479A ...
Страница 1960: ...A Appendix A 3 References SINAMICS G130 G150 1960 List Manual LH2 07 2016 A5E03263479A ...
Страница 1974: ...Index SINAMICS G130 G150 1974 List Manual LH2 07 2016 A5E03263479A ...
Страница 1975: ......