3
F
unction
d
iag
ram
s
3.9
B
rake cont
rol
SIN
A
MIC
S
G130
/G15
0
11
8
4
List
Manual (L
H2)
, 07
/2016
, A5E032634
79A
F
ig.
3
-75
27
01 – Basic brake control (r010
8.14
=
0)
- 2701 -
Function diagram
8
7
6
5
4
3
2
1
fp_2701_54_eng.vsd
DO: SERVO, VECTOR
S120/S150/G130/G150
14.03.16 V04.08.00
Brake control - Basic brake control (r0108.14 = 0)
n_stop n_thresh
0.0...210 000.0 [rpm]
p1226 (20.0)
r0060
n_set before filter
Pulse enable HW
OFF 1 present
OFF 3 present
Background
<1> Motor holding brake configuration (p1215)
0 = No motor holding brake being used.
1 = Motor holding brake acc. to sequence control.
2 = Motor holding brake always released.
3 = Motor holding brake like sequence control, connection via BICO.
<2> Priority assignment (high -> low): p1215, p0858, p0855, p0856, sequence control.
<3> If p1215 = 0, 2 -> t = 0 ms.
<4> Only if Safety Integrated is active (Double Motor Module: X22, Chassis: X41).
<5> For p1227 = 300 s, the monitoring function is deactivated.
<6> If an external motor holding brake is used, p1215 should be set to 3 and r0899.12 should be interconnected as control signal.
<7> r0046.21 = 0, as long as r0046.0 = 1 (OFF1 enable missing or power-on inhibit).
The signal generation is shown simplified.
<8> The internal signal includes signals that lead to OFF1 or OFF3 (e.g. BICO or fault response).
<9> If the brake is permanently applied or released (p0855, p0858 or p1215), the drive does not wait while the brake is released or applied.
<10> Only for SINAMICS S120.
STOP2 enable internal missing
r0046.21
[2634.1]
[2501.3]
p0855
1 = Unconditionally open the
holding brake
r0898.7
<3>
[2501.3]
p0856
1 = Enable speed controller
r0898.12
[2501.3]
p0852
1 = Operation enabled
r0898.3
[2501.3]
p0858 1 = Unconditionally close the holding brake
r0898.14
0...10 000 [ms]
p1217 (100)
1
T
0
0.000...300.000 [s]
p1227 (4.000)
T
0
p1215 = 2
1
0
1
0
T
0
1
1
1
<4>
T
0
0.000...10.000 [s]
p1228 (0.000)
[2814.2]
[2503.3]
[2503.3]
[2610.5]
[2610.8]
[5042.8]
[5730.4]
&
<5>
<1>
<2>
<2>
<6>
[2503.3]
<3>
<7>
<8>
[2503.7]
Q
Q
RESET
(Q=0)
SET
(Q=1)
Q
Q
RESET
(Q=0)
SET
(Q=1)
RESET
(Q=0)
Q
Q
SET
(Q=1)
Q
Q
RESET
(Q=0)
SET
(Q=1)
Q
Q
RESET
(Q=0)
SET
(Q=1)
0...10 000 [ms]
p1216 (100)
<1>
p1215 = 0
&
&
&
1
&
1 = Command, close holding brake
r0899.13
Close "normal" brake
1 = Open the holding brake
1 = Open the holding brake
r0899.12
Open brake
Close brake
r0063
n_act smooth
[4710.7]
r0063[0]
n_act unsmoothed
[4715.7]
1 = No coast down active
r0899.4
Pulse enable X21
[2503.7]
1 = Power-on inhibit active
r0899.6
Magnetizing completed
r0056.4
<9>
[2526.6]
Note: Braking signal diagnostic evaluation (p1278) only applies for SBC (Safe Brake Control) (controls the Safe Brake Relay).
<10>
<10>
<10>
<10>
<10>
[6030.2]
for VECTOR
<10>
r1438
n_ctrl n_set
[5030.8]
[5042.5]
for SERVO
Note: With VECTOR with activated "parallel circuit" Function Module (r0108.15 = 1), the holding brake may only be connected to a power unit (p7015).
Содержание SINAMICS G130
Страница 1: ...s SINAMICS SINAMICS G130 G150 List Manual 07 2016 Edition ...
Страница 2: ......
Страница 8: ...Preface SINAMICS G130 G150 8 List Manual LH2 07 2016 A5E03263479A ...
Страница 1940: ...4 Faults and alarms 4 2 List of faults and alarms SINAMICS G130 G150 1940 List Manual LH2 07 2016 A5E03263479A ...
Страница 1960: ...A Appendix A 3 References SINAMICS G130 G150 1960 List Manual LH2 07 2016 A5E03263479A ...
Страница 1974: ...Index SINAMICS G130 G150 1974 List Manual LH2 07 2016 A5E03263479A ...
Страница 1975: ......