r11294
CO: Free tec_ctrl 2 output signal / Ftec2 out_sig
Access level: 2
Calculated: -
Data type: FloatingPoint32
Can be changed: -
Scaling: PERCENT
Dynamic index: -
Unit group: -
Unit selection: -
Function diagram: 7030
Min:
- [%]
Max:
- [%]
Factory setting:
- [%]
Description:
Display and connector output for the output signal of the free technology controller 2.
p11297
CI: Free tec_ctrl 2 limit maximum signal source / Ftec2 lim max s_s
Access level: 3
Calculated: -
Data type: Unsigned32 /
FloatingPoint32
Can be changed: T, U
Scaling: PERCENT
Dynamic index: -
Unit group: -
Unit selection: -
Function diagram: 7030
Min:
-
Max:
-
Factory setting:
11291[0]
Description:
Sets the signal source for the maximum limit of the free technology controller 2.
Dependency:
See also: p11291
p11298
CI: Free tec_ctrl 2 limit minimum signal source / Ftec2 lim min s_s
Access level: 3
Calculated: -
Data type: Unsigned32 /
FloatingPoint32
Can be changed: T, U
Scaling: PERCENT
Dynamic index: -
Unit group: -
Unit selection: -
Function diagram: 7030
Min:
-
Max:
-
Factory setting:
11292[0]
Description:
Sets the signal source for the minimum limit of the free technology controller 2.
Dependency:
See also: p11292
p11299
CI: Free tec_ctrl 2 limit offset signal source / Ftec2 lim offs
Access level: 3
Calculated: -
Data type: Unsigned32 /
FloatingPoint32
Can be changed: T, U
Scaling: PERCENT
Dynamic index: -
Unit group: -
Unit selection: -
Function diagram: 7030
Min:
-
Max:
-
Factory setting:
0
Description:
Sets the signal source for the limit offset of the free technology controller 2.
r29018[0...1]
OA version / OA ver
Access level: 3
Calculated: -
Data type: Unsigned16
Can be changed: -
Scaling: -
Dynamic index: -
Unit group: -
Unit selection: -
Function diagram: -
Min:
-
Max:
-
Factory setting:
-
Description:
Displays the OA version.
Index:
[0] = Firmware version
[1] = Build increment number
Parameters
7.3 Parameters
SINAMICS G120XA converter
Operating Instructions, 03/2019, FW V1.0, A5E44751205B AB
705
Содержание SINAMICS G120XA
Страница 2: ......
Страница 12: ...Table of contents SINAMICS G120XA converter 10 Operating Instructions 03 2019 FW V1 0 A5E44751205B AB ...
Страница 104: ...Wiring 4 2 Control interfaces SINAMICS G120XA converter 102 Operating Instructions 03 2019 FW V1 0 A5E44751205B AB ...
Страница 916: ...Index SINAMICS G120XA converter 914 Operating Instructions 03 2019 FW V1 0 A5E44751205B AB ...
Страница 917: ......