p11271
Free tec_ctrl 2 actual value inversion / Ftec2 act v inv
Access level: 3
Calculated: -
Data type: Integer16
Can be changed: T
Scaling: -
Dynamic index: -
Unit group: -
Unit selection: -
Function diagram: 7030
Min:
0
Max:
1
Factory setting:
0
Description:
Sets the inversion of the actual value signal of the free technology controller 2.
Value:
0:
No inversion
1:
Inversion
r11272
CO: Free tec_ctrl 2 actual value after limiter / Ftec2 act v af lim
Access level: 2
Calculated: -
Data type: FloatingPoint32
Can be changed: -
Scaling: PERCENT
Dynamic index: -
Unit group: 9_4
Unit selection: p11226
Function diagram: 7030
Min:
- [%]
Max:
- [%]
Factory setting:
- [%]
Description:
Display and connector output for the actual value after the limiter of the free technology controller 2.
r11273
CO: Free tec_ctrl 2 system deviation / Ftec2 sys dev
Access level: 2
Calculated: -
Data type: FloatingPoint32
Can be changed: -
Scaling: PERCENT
Dynamic index: -
Unit group: 9_4
Unit selection: p11226
Function diagram: 7030
Min:
- [%]
Max:
- [%]
Factory setting:
- [%]
Description:
Display and connector output for the system deviation of the free technology controller 2.
p11274
Free tec_ctrl 2 differentiation time constant / Ftec2 D comp T
Access level: 2
Calculated: -
Data type: FloatingPoint32
Can be changed: T, U
Scaling: -
Dynamic index: -
Unit group: -
Unit selection: -
Function diagram: 7030
Min:
0.000 [s]
Max:
60.000 [s]
Factory setting:
0.000 [s]
Description:
Sets the time constant for the differentiation (D component) of the free technology controller 2.
Note
Value = 0: Differentiation is deactivated.
p11280
Free tec_ctrl 2 proportional gain / Ftec2 Kp
Access level: 2
Calculated: -
Data type: FloatingPoint32
Can be changed: T, U
Scaling: -
Dynamic index: -
Unit group: -
Unit selection: -
Function diagram: 7030
Min:
0.000
Max:
1000.000
Factory setting:
1.000
Description:
Sets the proportional gain (P component) of the free technology controller 2.
Note
Value = 0: The proportional gain is deactivated.
Parameters
7.3 Parameters
SINAMICS G120XA converter
Operating Instructions, 03/2019, FW V1.0, A5E44751205B AB
703
Содержание SINAMICS G120XA
Страница 2: ......
Страница 12: ...Table of contents SINAMICS G120XA converter 10 Operating Instructions 03 2019 FW V1 0 A5E44751205B AB ...
Страница 104: ...Wiring 4 2 Control interfaces SINAMICS G120XA converter 102 Operating Instructions 03 2019 FW V1 0 A5E44751205B AB ...
Страница 916: ...Index SINAMICS G120XA converter 914 Operating Instructions 03 2019 FW V1 0 A5E44751205B AB ...
Страница 917: ......