p5611
Pe energy-saving properties general / Pe properties gen
G120X_PN
Access level: 3
Calculated: -
Data type: Unsigned32
Can be changed: T
Scaling: -
Dynamic index: -
Unit group: -
Unit selection: -
Function diagram: 2381, 2382
Min:
-
Max:
-
Factory setting:
0000 bin
Description:
Sets the general properties for energy-saving.
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Inhibit PROFIenergy control commands
Yes
No
-
01
Drive initiates OFF1 when transitioning to energy-saving
mode
Yes
No
-
02
Trans to energy-saving mode from PROFIdrive state S3/4
poss
Yes
No
-
Note
Pe: PROFIenergy profiles
PROFIdrive state S4: operation
p5612[0...1]
Pe energy-saving properties mode-dependent / Pe properties mod
G120X_PN
Access level: 3
Calculated: -
Data type: Unsigned32
Can be changed: T
Scaling: -
Dynamic index: -
Unit group: -
Unit selection: -
Function diagram: -
Min:
-
Max:
-
Factory setting:
[0] 0110 bin
[1] 0000 bin
Description:
Sets the mode-dependent properties for energy-saving.
Index:
[0] = Reserved
[1] = Mode 2
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Reserved
Yes
No
-
Note
Pe: PROFIenergy profiles
r5613.0...1
CO/BO: Pe energy-saving active/inactive / Pe save act/inact
G120X_PN
Access level: 3
Calculated: -
Data type: Unsigned8
Can be changed: -
Scaling: -
Dynamic index: -
Unit group: -
Unit selection: -
Function diagram: 2382
Min:
-
Max:
-
Factory setting:
-
Description:
Display and binector output for the state display PROFIenergy energy saving active or inactive.
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Pe active
Yes
No
-
01
Pe inactive
Yes
No
-
Note
Bit 0 and bit 1 are inverse of one another.
Pe: PROFIenergy profiles
Parameters
7.2 Parameter list
SINAMICS G120X converter
858
Operating Instructions, 06/2019, FW V1.01, A5E44751209B AC
Содержание SINAMICS G120X
Страница 2: ......
Страница 152: ...Wiring 4 2 Control interfaces SINAMICS G120X converter 150 Operating Instructions 06 2019 FW V1 01 A5E44751209B AC ...
Страница 940: ...Parameters 7 3 ASCII table SINAMICS G120X converter 938 Operating Instructions 06 2019 FW V1 01 A5E44751209B AC ...
Страница 1114: ...Appendix A 1 Manuals and technical support SINAMICS G120X converter 1112 Operating Instructions 06 2019 FW V1 01 A5E44751209B AC ...
Страница 1147: ......