r2130[0...63]
Fault time received in days / t_fault recv days
Access level: 3
Calculated: -
Data type: Unsigned16
Can be changed: -
Scaling: -
Dynamic index: -
Unit group: -
Unit selection: -
Function diagram: 8060
Min:
-
Max:
-
Factory setting:
-
Description:
Displays the system runtime in days when the fault occurred.
Dependency:
See also: r0945, r0947, r0948, r0949, r2109, r2133, r2136, p8401
NOTICE
The time comprises r2130 (days) and r0948 (milliseconds).
The value displayed in r2130 refers to January 1, 1970
Note
The buffer parameters are cyclically updated in the background (refer to status signal in r2139).
r2131
CO: Actual fault code / Act fault code
Access level: 2
Calculated: -
Data type: Unsigned16
Can be changed: -
Scaling: -
Dynamic index: -
Unit group: -
Unit selection: -
Function diagram: 8060
Min:
-
Max:
-
Factory setting:
-
Description:
Displays the code of the oldest active fault.
Dependency:
See also: r3131, r3132
Note
0: No fault present.
r2132
CO: Actual alarm code / Actual alarm code
Access level: 2
Calculated: -
Data type: Unsigned16
Can be changed: -
Scaling: -
Dynamic index: -
Unit group: -
Unit selection: -
Function diagram: 8065
Min:
-
Max:
-
Factory setting:
-
Description:
Displays the code of the last alarm that occurred.
Note
0: No alarm present.
r2133[0...63]
Fault value for float values / Fault val float
Access level: 3
Calculated: -
Data type: FloatingPoint32
Can be changed: -
Scaling: -
Dynamic index: -
Unit group: -
Unit selection: -
Function diagram: 8060
Min:
-
Max:
-
Factory setting:
-
Description:
Displays additional information about the fault that occurred for float values.
Dependency:
See also: r0945, r0947, r0948, r0949, r2109, r2130, r2136
Note
The buffer parameters are cyclically updated in the background (refer to status signal in r2139).
Parameters
7.2 Parameter list
SINAMICS G120X converter
774
Operating Instructions, 06/2019, FW V1.01, A5E44751209B AC
Содержание SINAMICS G120X
Страница 2: ......
Страница 152: ...Wiring 4 2 Control interfaces SINAMICS G120X converter 150 Operating Instructions 06 2019 FW V1 01 A5E44751209B AC ...
Страница 940: ...Parameters 7 3 ASCII table SINAMICS G120X converter 938 Operating Instructions 06 2019 FW V1 01 A5E44751209B AC ...
Страница 1114: ...Appendix A 1 Manuals and technical support SINAMICS G120X converter 1112 Operating Instructions 06 2019 FW V1 01 A5E44751209B AC ...
Страница 1147: ......