20:
Analog se no main setpoint
21:
Analog se motor potentiometer
22:
Analog se analog setpoint
23:
Analog se fixed speed setpoint
26:
Analog se fieldbus
27:
Analog se analog setpoint 2
30:
Fixed speed se no main setpoint
31:
Fixed speed se motor potentiometer
32:
Fixed speed se analog setpoint
33:
Fixed speed se fixed speed setpoint
36:
Fixed speed se fieldbus
37:
Fixed speed se analog setpoint 2
60:
Fi no main setpoint
61:
Fi motor potentiometer
62:
Fi analog setpoint
63:
Fi fixed speed setpoint
66:
Ffieldbus
67:
Fi analog setpoint 2
70:
Analog setpoint 2 + no main setpoint
71:
Analog setpoint 2 + motor potentiometer
72:
Analog setpoint 2 + analog setpoint
73:
Analog setpoint 2 + fixed speed setpoint
76:
Analog setpoint 2 + fieldbus
77:
Analog setpoint 2 + analog setpoint 2
200:
Analog output connection
Dependency:
When changing this parameter, the following settings are influenced:
See also: p1070, p1071, p1075, p1076
CAUTION
If p1000 is selected as the main setpoint of the fieldbus, the following BICO interconnection is set automatically:
p2051[1] = r0063
NOTICE
The parameter is possibly protected as a result of p0922.
For PROFIBUS/PROFINET Control Units, the following applies: The parameter can be freely set by setting p0922 =
999.
When executing a specific macro, the corresponding programmed settings are made and become active.
p1000[0...n]
Speed setpoint selection / n_set sel
G120X_USS
Access level: 1
Calculated: -
Data type: Integer16
Can be changed: T
Scaling: -
Dynamic index: CDS, p0170
Unit group: -
Unit selection: -
Function diagram: -
Min:
0
Max:
200
Factory setting:
2
Parameters
7.2 Parameter list
SINAMICS G120X converter
Operating Instructions, 06/2019, FW V1.01, A5E44751209B AC
607
Содержание SINAMICS G120X
Страница 2: ......
Страница 152: ...Wiring 4 2 Control interfaces SINAMICS G120X converter 150 Operating Instructions 06 2019 FW V1 01 A5E44751209B AC ...
Страница 940: ...Parameters 7 3 ASCII table SINAMICS G120X converter 938 Operating Instructions 06 2019 FW V1 01 A5E44751209B AC ...
Страница 1114: ...Appendix A 1 Manuals and technical support SINAMICS G120X converter 1112 Operating Instructions 06 2019 FW V1 01 A5E44751209B AC ...
Страница 1147: ......