Operating Instructions, 12/2014, A5E32923362A
Freely selecting the signal interconnection of the telegram
The signals in the telegram can be freely interconnected.
Procedure
Proceed as follows to change the signal interconnection of a telegram:
1.
Use STARTER or the IOP to set parameter p0922 = 999.
2.
Use STARTER or the IOP to set parameter p2079 = 999.
3.
Interconnect additional PZD send words and PZD receive words with signals of your
choice via parameters r2050 and p2051.
Parameter
Description
p0922
PROFIdrive telegram selection
999: Free telegram (message frame) configuration
p2079
PROFIdrive PZD telegram selection extended
999: Free telegram (message frame) configuration
r2050[0…11] PROFIdrive PZD receive word
Connector output to interconnect the PZD (setpoints) in the word format received
from the PROFIdrive controller.
p2051[0…11] PROFIdrive PZD send word
Selection of the PZD (actual values) in the word format to be sent to the PROFIdrive
controller.
For further information refer to the function block diagrams 2468 and 2470 of the List
Manual.
6.5.1.4
Data structure of the parameter channel
Structure of the parameter channel
The parameter channel consists of four words. 1st and 2nd word transfer the parameter
number and index as well as the type of job (read or write) The 3rd and 4th word contains
the parameter contents. The parameter contents can be 16-bit values (such as baud rate) or
32-bit values (e.g. CO parameters).
Bit 11 in the 1st word is reserved and is always assigned 0.
You can find examples of telegrams at the end of this section.
Содержание SINAMICS G120P
Страница 1: ......
Страница 2: ......
Страница 8: ...Preface Inverter cabinet units 8 Operating Instructions 12 2014 A5E32923362A ...
Страница 16: ...Table of contents Inverter cabinet units 16 Operating Instructions 12 2014 A5E32923362A ...
Страница 255: ...Operation 6 8 Communication via RS485 Inverter cabinet units Operating Instructions 12 2014 A5E32923362A 255 ...
Страница 432: ...Application examples Inverter cabinet units 432 Operating Instructions 12 2014 A5E32923362A ...
Страница 496: ......