Commissioning
5.5 Restoring the factory setting
Converter with control units CU250D-2
84
Operating Instructions, 04/2015, FW V4.7.3, A5E34261542B AB
Procedure with Startdrive
To reset the safety function settings to the factory setting without changing the standard
settings, proceed as follows:
1.
Go online.
2.
Select "Commissioning".
3.
Select "Backing up/reset".
4.
Select "Safety parameters are reset".
5.
Click the "Start" button.
6.
Enter the password,for the safety functions.
7.
Confirm that the parameters have been saved (RAM to ROM).
8.
Go offline.
9.
Switch off the inverter supply voltage.
10.Wait until all LEDs on the inverter go dark.
11.Switch on the inverter supply voltage again.
You have restored the safety functions in the inverter to the factory settings.
5.5.3
Restore the settings to the factory settings (without safety functions)
Restoring the inverter to the factory setting
Procedure with STARTER
Proceed as follows to reset the inverter to factory settings:
1.
Go online
2.
Select the button
You have reset the inverter to factory settings.