Advanced commissioning
7.6 Basic positioner and position control
Converter with control units CU250D-2
202
Operating Instructions, 04/2015, FW V4.7.3, A5E34261542B AB
7.6.8
Jogging
7.6.8.1
Jog velocity
Description
Only input a setpoint velocity for the converter for velocity jog. With the signal "Jogging 1" or
"Jogging 2", the converter accelerates the axis to the relevant setpoint velocity. The
converter stops the axis when the respective "Jog" signal returns to zero.
Figure 7-41 Jog velocity