Table 7-30
PM240-2, PT, frame size F, 3 AC 380 V … 480 V
Article number without filter
Article number with filter
6SL3211-1PE31-1UL0
6SL3211-1PE31-1AL0
LO base load power
132 kW
LO base load input current
242 A
LO base load output current
250 A
HO base load power
110 kW
HO base load input current
218 A
HO base load output current
205 A
Fuse according to IEC/UL
Fuse according to IEC/UL, Class J
3NA3252 (315 A)
350 A
Power loss without filter
2.98 kW
1)
Power loss with filter
3.02 kW
1)
Required cooling air flow
153 l/s
Weight without filter
63.5 kg
Weight with filter
68 kg
1)
Approx. 2.6 kW through the heatsink