8.6.5
NAMUR message word
Function description
Fault word according to the VIK-NAMUR definition (MELD_NAMUR)
Bit Significance
P No.
0
1 = Control Unit signals a fault
p2051[5] = r3113
1
1 = line fault: Phase failure or inadmissible voltage
2
1 = DC link overvoltage
3
1 = Power Module fault, e.g. overcurrent or overtemperature
4
1 = converter overtemperature
5
1 = ground fault/phase fault in the motor cable or in the motor
6
1 = motor overload
7
1 = communication error to the higher-level control system
8
1 = fault in a safety-relevant monitoring channel
10 1 = fault in the internal converter communication
11 1 = line fault
15 1 = other fault
Advanced commissioning
8.6 Drive control via PROFIBUS or PROFINET
Distributed converter for SIMOGEAR geared motors
Operating Instructions, 10/2020, FW V4.7 SP13, A5E31298649B AL
193