Commissioning
5.2 Restoring the factory settings
SINAMICS G110D
Operating Instructions, 07/2016, FW V3.63, A5E36768472B AB
63
5.2
Restoring the factory settings
If nothing else works, restore the factory settings!
You can restore the factory settings using parameter P0970.
Parameter or proce-
dure
Description
P0003 = 1
User access level
1: Standard level
P0010 = 30
Commissioning parameter
30: Factory setting, parameter transfer
P0970 = 1
Restore factory settings
1: Restore the factory parameter settings
IOP - select factory
restart from the extras
menu.
The IOP will display a message stating that a factory reset is taking place
and display a progress bar. When completed the display will display a mes-
sage that the factory reset has been successfully completed.
STARTER
Displays a progress bar.
Note
Data transfer is interrupted while the factory parameter settings are being restored.
The following parameters remain unchanged even after the factory settings have been
restored:
•
P0014 Storage mode
•
P0100 Europe / North America
•
P0201 Power stack code number
•
Communication parameters
•