![Siemens SINAMICS G Скачать руководство пользователя страница 473](http://html.mh-extra.com/html/siemens/sinamics-g/sinamics-g_list-manual_378180473.webp)
Signals and monitoring functions
Function diagrams
2-473
Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Picture 2-88 8010 – Speed messages
n
- 8010 -
Function diagram
8
7
6
5
4
3
2
1
fp_S01_8010_en.vsd
DO: VECTOR
SINAMICS G
17.12.04
V02.02.00
Messages and monitoring functions - speed messages/signals
r0063
n_act smooth
r2169
n_act smooth signal
[8010.5]
[8013.2]
0.00...60 000.00 RPM
p2162[D] (600.00)
0.00...300.00 RPM
p2140[D] (90.00)
0.00...210 000.00 RPM
p2155[D] (900.00)
0.00...210 000.00 RPM
p2161[D] (5.00)
r2169
n_act sm
ooth signal
0...1 000 000 ms
p2153 (0)
+
–
Priority
1 RESET
2 SET
0T
0.0...500.0 m
s
p2166[D] (200.0)
0.00...600.00 RPM
p2163[D] (90.00)
0.00...200.00 RPM
p2164[D] (1.50)
Smoothing
[6010.6]
[8010.2]
From setpoint
limiting
[3050.8]
F07901 "motor overspee
d
"
n
p0115[1] (125.00 µs)
0
1
0
1
0
1
0
1
0
1
0.00...210 000.00 RPM
p2141[D] (5.00)
0
1
0.000...300.000 RPM
p2142[D] (2.00)
n_act > n_max
r2197.6
Speed setpoint -
actual value deviation
within tolerance t_off
r2197.7
[2534.3]
Ramp-up/ramp-down completed
r2199.5
[2537.3]
n_set > 0
r2198.5
[2536.3]
|n_act| < p2161
r2199.0
|n_act|
≤
p2155
r2197.1
[2534.3]
f or n comparison value
reached or exceeded
r2199.1
[2537.3]
[2537.3]
p0115[3] (4000.00 µs)
[3080.8]
+
n_limit pos effective
r1084
n_limit neg effective
r1087
T0
0...10 000 ms
p2156[D] (0)
SET
(Q=1)
RESET
(Q=0)
Q
Q
n_setp
r1170
p2151[C]
0
[3060.1]
[3080.8]
[2534.3]
0
1
0.00...300.00 RPM
p2150[D] (2.00)
n_act
≥
0
r2197.3
[2534.3]
0
|n_act| > p2155
r2197.2
1
0
1
<2>
Calculated.
<1>
Only for activated function module "expanded
messages/monitoring functions"
(r0108.17 = 1).
|n_set|
≤
p2161
r2198.4
[2536.3]
n_set 2
0
p2154[C]
p2149.0[D]
A07903
"Motor speed
deviation"
1
<1>
<2>
<2>
<2>
<2>
<2>
p0115[3] (<4>)
p0115[1] (<3>)
<3>
Dependent on the drive unit, 250 or 400 µs.
<
4
>
Dependent on the driv
e unit
,
1000 or 1600 µs
.
(0)
RFG active
p2148[C]
0
1
[2537.3]
0.0...10000.0 ms
p2167[D] (200.0)
T0
Speed setpoint -
actual value deviation
within tolerance t_on
r2199.4
1 = RESET
A07903 is only signals for p2149.0 = 1
and r2197.7 = 0.
Содержание SINAMICS G
Страница 1: ...List Manual 12 2004 Edition sinamics SINAMICS G ...
Страница 2: ......
Страница 8: ...Preface Preface 8 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 680: ...List of Abbreviations Abbreviations 680 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 686: ...References References 686 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 696: ...Index Index 696 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...