Picture 2-48 2707 – Expanded brake control/opening and closing a brake (r0108.14 = 1)
- 2707 -
8
7
6
5
4
3
2
1
fp_S01_2707_en.vsd
DO: VECTOR
SINAMICS G
17.12.04
V02.02.00
Brake control - expanded brake control/opening and closing a brake (r0108.14 = 1)
Function diagram
<1> Motor holding brake configuration
0 = No brake or brake always closed (brake connected to the power module)
1 = Brake control active (brake connected to the power module)
2 = Brake always open (brake connected to the power module)
3 = Brake control active (brake connection can be interconnected using BICO).
Note:
Not all power modules have the ability to connect a motor brake. In this case p1215 is set to 3 and the brake is controll
ed through
a digital output (e.g. TM31).
<3> These blocks/modules are evaluated with the same sampling rate as the brake control and therefore may only be used to
individually adapt the brake control.
(0)
OR logic operation
p1279[0]
(0)
p1279[1]
1
Brake, result of
the O
R
logic operation
1229.10
(0)
AND logic operation
p1279[2]
(0)
p1279[3]
Brake, result of
the AND
logic operation
1229.11
<3>
&
Background
Refer to [1020.7]
<2> Priority assignment (high -> low): p1215, p1219, p0855, close brake from the standstill detection, p1218.
Magnetizing completed
r0056.4
T0
0.000...300.000
s
p1277(0.000)
Brake open threshold
(1)
p1220
(1)
Open brake
p1218[0]
0
1
Brake open threshold
0.00...200.00%
p1221(0.00)
Open brake (internal)
&
Braking threshold exceeded
r1229.6
1
(1)
p1218[1]
&
[2711.1]
<2>
p1215 = 2
<1>
[2501.7]
p0855
1 = Unconditionally open the holding brake
r0898.7
[2501.7]
p0856
1 = Enable speed controller
r0898.12
(0)
p1219[2]
(r1229.9)
p1219[3]
1
Close brake (internal)
(0)
p1219[1]
(0)
Immediately close brake
p1219[0]
1
0
1
p1275.00 (0)
1
0
1
p1275.01 (0)
Pulses or speed controller inhibited
r1229.9
1
&
Request pulse enable
[2711.1]
[2711.8]
[2704.8]
Close brake from standstill detection
<1>
p1215 = 0
1
<2>
Содержание SINAMICS G
Страница 1: ...List Manual 12 2004 Edition sinamics SINAMICS G ...
Страница 2: ......
Страница 8: ...Preface Preface 8 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 680: ...List of Abbreviations Abbreviations 680 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 686: ...References References 686 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 696: ...Index Index 696 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...