Connecting
4.1 Connecting the device
SINAMICS CONNECT
30
Operating Instructions, 10/2018, A5E45421408
NOTICE
Ferrite required at USB cables
The interference immunity of the device according to the data in the technical specifications
is only guaranteed when the cables at USB and micro USB ports are equipped with a ferrite
magnet.
•
Use only USB cables equipped with a ferrite magnet.
4.1.2
Connecting the power supply
Connect the power supply to interface X80 of the device.
Note
The power supply must be adapted to the input data of the device, see Section "General
technical specifications (Page 85)".
For more information about the requirements of power supply, see Chapter "Technical data
(Page 85)".
Requirement
●
You are using the supplied terminal.
●
A two-core cable with a cable cross-section of AWG 18 to 13 (0.75 mm
2
to 2.5 mm
2
).
●
A slotted screwdriver with a 3 mm blade.
Note
•
The power cable is not provided at delivery.
•
Use a copper conductor suitable for temperatures ≤ 75 °C.
Procedure
1.
Switch off the power supply on the device.
2.
Connect the cores of the power supply.