Procedure
1. Copy the connection key from the corresponding email to the IPC.
2. Open the "MindConnect Bridge Configuration" application on the IPC via the Remote
Desktop connection.
3. In the "Onboarding information" selection list, select the "Add configuration" entry.
The "MindSphere Onboarding Information" window is opened.
4. Click on "Read from file".
5. Select the connection key.
6. Confirm your entry with "OK".
7. Save the configuration using "Configuration > Save".
Result
The information for connecting the connectivity module to MindSphere has been configured.
You can read the connection status in the "MindConnect Bridge" application. You can see that
a connection has been successfully established with MindSphere in status messages "Last
service state: MAIN" and "Last MCL status: Success" in the status line in the lower part of the
program window.
7.7
Replacing parameter lists and alarm lists
The parameter lists and alarm lists must be replaced after a new firmware version has been
installed. Then restart service "Drive System Connect".
Commissioning
7.7 Replacing parameter lists and alarm lists
SINAMICS CONNECT 500
Operating Instructions, 10/2019
31
Содержание SINAMICS CONNECT 500
Страница 2: ......
Страница 8: ...Introduction 1 2 Naming convention SINAMICS CONNECT 500 6 Operating Instructions 10 2019 ...
Страница 14: ...Safety instructions 2 6 Security recommendations SINAMICS CONNECT 500 12 Operating Instructions 10 2019 ...
Страница 40: ...Commissioning 7 9 Completing commissioning SINAMICS CONNECT 500 38 Operating Instructions 10 2019 ...
Страница 42: ...Operation 8 1 Data evaluation with SIDRIVE IQ SINAMICS CONNECT 500 40 Operating Instructions 10 2019 ...
Страница 54: ...Service Support SINAMICS CONNECT 500 52 Operating Instructions 10 2019 ...
Страница 59: ......