![Siemens SIMOTION TM15 Скачать руководство пользователя страница 51](http://html.mh-extra.com/html/siemens/simotion-tm15/simotion-tm15_commissioning-manual_384566051.webp)
TM15 / TM17 High Feature Operating Manual
Commissioning Manual, 05/2009
51
Error messages
4
Introduction
The error messages generated by the TM15 or TM17 High Feature modules are reported
cyclically to the SIMOTION Motion Control System via the module status word as well as the
diagnostic interrupt. The input address of the status word is identical to the start address (I-
address) of the module.
Status word structure
The error bit corresponds to bit 9 of the module status word.
ERR = 0:
No error
ERR = 1:
Error. The cause of error is indicated via
error bits MF, PS, and
FPGA.
For hotline purposes, drive parameter
P2122 contains a
detailed error code.
Error class if ERR = 1 is set
MF: Internal module error
PS: No I/O power supply
FPGA: Error in FPGA code
Bit
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Function -
-
-
-
-
-
ERR SYNC -
-
-
-
-
FPGA PS
MF
-: Reserved, must not be used
ERR
Error bit; indicates that the module is not
ready; more details are specified with bits
MF, PS and FPGA
SYNC
SYNC = 1 indicates that the TM1x module is
synchronized
Содержание SIMOTION TM15
Страница 6: ......
Страница 44: ......
Страница 50: ......
Страница 68: ......
Страница 84: ......
Страница 88: ......
Страница 90: ......
Страница 94: ......
Страница 98: ...SIMOTION SIMOTION SCOUT TM15 TM17 High Feature Operating Manual Commissioning Manual 05 2009 98 ...
Страница 99: ...SIMOTION SIMOTION SCOUT TM15 TM17 High Feature Operating Manual Commissioning Manual 05 2009 99 ...