Configuration/programming
2.3 Accessing inputs and outputs in a user task
TM15 / TM17 High Feature Operating Manual
Commissioning Manual, 05/2009
33
Refer to the following figure for the offset in the example.
Figure 2-8
SCOUT – graphical configuration screen form for the TM17 (SIMOTION)
Input DI
The base "I-address" of the TM17 High Feature is "288". Now add the offset of 3.0. For DI 0,
the resulting address is "291.0".
Output DO
The base "O-address" of the TM17 High Feature is "280". Now add the offset of 3.1. For DO
1, the resulting address is "283.1".
The procedures for generating symbolic variables and for using the process image or direct
I/O access are described in the SIMOTION SCOUT Manual.
Note
You cannot use I/O variables to output to a digital output that is being used simultaneously
by an Output Cam or Cam Track technology object.
An error message will be output when the project is downloaded to the target system.
Please also note that the Terminal Module must have ramped up before it is accessed via
I/Os. You can also configure an error strategy for I/O (CPU stop, substitute value or last
value). Note that byte-specific setting is the minimum possible setting.
You cannot assign a substitute value for an output byte if individual bits have been allocated
to an Output Cam or Cam Track technology object.
See also
Power Up and Synchronization with the User Program (Page 37)
Содержание SIMOTION TM15
Страница 6: ......
Страница 44: ......
Страница 50: ......
Страница 68: ......
Страница 84: ......
Страница 88: ......
Страница 90: ......
Страница 94: ......
Страница 98: ...SIMOTION SIMOTION SCOUT TM15 TM17 High Feature Operating Manual Commissioning Manual 05 2009 98 ...
Страница 99: ...SIMOTION SIMOTION SCOUT TM15 TM17 High Feature Operating Manual Commissioning Manual 05 2009 99 ...