![Siemens SIMOTION TM15 Скачать руководство пользователя страница 15](http://html.mh-extra.com/html/siemens/simotion-tm15/simotion-tm15_commissioning-manual_384566015.webp)
Description
1.2 Properties: TM15 / TM17 High Feature
TM15 / TM17 High Feature Operating Manual
Commissioning Manual, 05/2009
15
Table 1- 1
Comparison table for module selection
Function
TM15
1
TM15 DI/DO
1
TM17 High Feature
1
System integration
Use only in conjunction with
SIMOTION (SIMOTION D,
CX32 or CU310/CU320 with
SIMOTION as the higher-
level controller)
Use also in conjunction with
CU310/CU320 (without
SIMOTION)
Use only in conjunction with
SIMOTION (SIMOTION D,
CX32 or CU310/CU320 with
SIMOTION as the higher-
level controller)
Functionality
24 DI/O can be
parameterized on a channel-
specific basis as DI, DO,
output of an output cam, or
input of a measuring input;
DI/O can only be addressed
via SIMOTION controller
24 DI/DO-channels can be
parameterized as DI or DO;
DI/DO can only be
interconnected via BICO
technology
16 DI/O can be
parameterized on a channel-
specific basis as DI, DO,
output of an output cam, or
input of a measuring input;
DI/O can only be addressed
via SIMOTION controller
Short response time
X
X
X
Number of I/O channels
24
24
16
Electrical isolation of inputs
and outputs
X
X
-
Grouping of channels
3 groups for every 8
channels
3 groups for every 8
channels
2 groups for every 8
channels
Inputs of measuring input
(single measurement)
X
-
X
Inputs of measuring input
(cyclic measurement)
-
-
X
Several measuring inputs per
axis
X
-
X
One measuring input for
several axes
X
-
X
Measuring on virtual axes
X
-
X
Outputs of the output cams X
-
X
Resolution - inputs of
measuring input
Typ. 125 µs
2
(firmware support)
Not applicable
1 µs (hardware support)
Resolution -
outputs of output cam
Typ. 125 µs
2
(firmware support)
Not applicable
1 µs
(hardware
support)
Accuracy - inputs of
measuring input
Typ. ±125 µs
2
Not applicable
≤ ±1 µs
Accuracy - outputs of output
cam
Typ. ±125 µs
2
Not applicable
≤ ±10 µs
Input filtering
50 µs
50 µs
1 µs or 125 µs, user-
assignable
Enable via external signal
-
Not applicable
6 channels, max.
1
"X" = available; "-" = not available.
2
corresponds to the DRIVE CLiQ cycle clock in use (125 μs, typical)
Содержание SIMOTION TM15
Страница 6: ......
Страница 44: ......
Страница 50: ......
Страница 68: ......
Страница 84: ......
Страница 88: ......
Страница 90: ......
Страница 94: ......
Страница 98: ...SIMOTION SIMOTION SCOUT TM15 TM17 High Feature Operating Manual Commissioning Manual 05 2009 98 ...
Страница 99: ...SIMOTION SIMOTION SCOUT TM15 TM17 High Feature Operating Manual Commissioning Manual 05 2009 99 ...