Supplementary system components
6.10 CUA31/CUA32 control unit adapter
SIMOTION D4x5-2
132
Manual, 02/2012
6.10
CUA31/CUA32 control unit adapter
Properties of the CUA31/CUA32
You can connect power modules in blocksize format via DRIVE-CLiQ to the D4x5-2 control
units using the CUA31/CUA32 adapter modules.
The CUA32 adapter module also has an additional encoder interface for a HTL, TTL or SSI
encoder.
Table 6- 39 Number of interfaces on the adapter modules
Interface
CUA31
1)
CUA32
DRIVE-CLiQ interface
3
3
EP terminals/temperature sensor connection
1
1
Power module interface (PM-IF)
1
1
24 V electronic power supply
1
1
Encoder interface (HTL, TTL, SSI)
Only SSI encoders without incremental tracks may be
operated.
0
1
DRIVE-CLiQ cable length, max.
100 m
100 m
1)
CUA31 with order number 6SL3040-0PA00-0AAx (x ≥ 1 required)
CAUTION
The 50 mm clearances above and below the components must be observed. The
ventilation openings may not be covered by connecting cables.
Additional references
You will find more information on the CUA31/CUA32 control unit adapter in the
SINAMICS S120 AC Drive Manual.
Содержание SIMOTION TB30
Страница 10: ...Table of contents SIMOTION D4x5 2 10 Manual 02 2012 ...
Страница 36: ...Description 1 9 CompactFlash card SIMOTION D4x5 2 36 Manual 02 2012 ...
Страница 46: ...Operator control hardware 2 3 7 segment and LED displays SIMOTION D4x5 2 46 Manual 02 2012 ...
Страница 72: ...Interfaces 3 10 USB interfaces SIMOTION D4x5 2 72 Manual 02 2012 ...
Страница 134: ...Supplementary system components 6 11 DMC20 DRIVE CLiQ hub SIMOTION D4x5 2 134 Manual 02 2012 ...
Страница 142: ...Standards and approvals A 3 Safety of electronic controllers SIMOTION D4x5 2 142 Manual 02 2012 ...
Страница 150: ...Index SIMOTION D4x5 2 150 Manual 02 2012 ...