4.2
SIMOTION D for AddOn → SIMATIC S7
4.2.1
Common
Table 4-19
SIMOTION → SIMATIC S7, Common
PZD
Signal name
Unit
Format Remark
1
ZSW1_Common_PLC
-
WORD
Status word
see below, Table "ZSW1_Common_PLC"
2
FAULT1
-
DWORD Error message 1
from AddOn technology, see Chapter Error list AddOn
3
4
FAULT2
-
DWORD Error message 2
from AddOn technology, see Chapter Error list AddOn
5
6
INFO_NO_AUTO_START
-
DWORD Information about SAM mode start
see below, Table "INFO_NO_AUTO_START"
7
8
PARSET_OUT
1...99
SINT
Parameter set confirmation
Confirmation of the number of the active parameter set.
1: Parameter set 1
2: Parameter set 2
3: Parameter set 3
4: Parameter set 4
9
IMPNT
mm
DINT
Current immersion point value
Either the internal or the external immersion point is
used as the current immersion point, depending on the
IMPNT_EXT_ACTIVE control bit.
The value is only meaningful when STS is selected.
10
11-12 -
Reserved
Communication interface to SIMATIC S7
4.2 SIMOTION D for AddOn → SIMATIC S7
SC integrated STS, GSU
Operating Instructions, 07/2019, A5E48271265B AA
97