Name
Type Data
type
Unit-global variables of "AddOn"
Meaning
iS_Corr
IN
INT
trolley_sc_s_corr
Distance correction
Trolley_IO_PQW
OUT
ARRAY
[0..5] OF
word
addon_trolley_send
Output array for the Trolley block
(see Figure 5-13 Address list in
3.3.2.7
FB_IntpoPLCToAddOn
Symbol
)%B,QWSR3/&7R$GG2Q
$55$<
,QWSRB,2B3,:
ER7UDMHFWRU\B(QDEOH7UDQVIHU
%22/
ER7UDMHFWRU\B,QGH[B5FY
%<7(
Figure 3-21
FB_IntpoPLCToAddOn
Task
The "FB_IntpoPLCToAddOn" block reads the input area from the PROFIBUS DP / PROFINET
PN for the Intpo block and separates the array into words and bits.
Connections
The outputs must be connected to the inputs of the DCC_SCINTPO DCC block using the unit-
global variables of the "AddOn" MCC source file.
Table 3-25
FB_IntpoPLCToAddOn connections
Name
Type Data
type
Unit-global variables of "AddOn"
Meaning
Intpo_IO_PIW
IN
ARRAY
[0..5] OF
WORD
addon_intpo_receive
Input array for the Intpo block
boTrajectory_EnableTransfer
Out
BOOL
intpo_SC_Index_Snd
Activate transfer of interpola‐
tion points
boTrajectory_Index_Rcv
Out
BYTE
intpo_SC_Count
Received interpolation point
number
Overview of the software
3.3 Sway control function blocks
SC integrated STS, GSU
66