E65 (Bit -/-) Sway control off (start)
The set activation velocity (P146) has not been reached or the sway control ON delay (P147)
has not yet elapsed, in order to start the sway-control function. This warning is only triggered
in manual mode (MAN).
Error type:
Alarm
Remedy:
-
E66 (Bit -/-) Sway control only when stopping
The SC_WHEN_STOP control bit is set.
Error type:
Alarm
Remedy:
Reset the control bit
E67 (Bit -/-) Controlled stop active
The CONTROLLED_STOP control bit is set.
Error type:
Alarm
Remedy:
Reset the control bit
10.5.3.8
SIMOCRANE CeCOMM diagnostic program
Operating errors in the "Monitor" function are normally displayed in the monitor status line. An
example is the "Display screen not assigned" message.
10.5.3.9
Troubleshooting/FAQs
Scenario
Possible causes and remedy
After completion of a trolley movement,
an excessive residual sway remains.
The actual pendulum length differs greatly from the internally calculated effective
pendulum length (screen 01 in the SIMOCRANE CeCOMM diagnostic program).
Recalibrate the hoisting height (commissioning steps 2 and 3). Check the hoist
position P169 (permitted residual sway) and possibly set a smaller value.
Sway control system starts swaying mo‐
tions.
Check acceleration and deceleration ramps of the converter, remove any round‐
ings and check the control parameters of the converter. Set the alignment of the
camera (commissioning step 1).
Residual swaying motions are always or
occasionally too large.
Check ramps and speed controller of the converter.
Empty main menu (space bar) in the SI‐
MOCRANE CeCOMM diagnostic pro‐
gram
License is damaged or missing. Error E2 "Copy protection damaged" is displayed
on the "Errors" display screen ("E" key).
→ Check licenses
10.5.4
Error list TLS
In this section, the errors for the TLS functionalities follow. They are all contained in error word
2 (output FAULT2 of DCC block DCC_SCCOMMON).
Alarm, error, and system messages
10.5 Error messages
SC integrated STS, GSU
Operating Instructions, 07/2019, A5E48271265B AA
387