E24 (Bit -/-) Forward limit switch switches incorrectly, trolley
The limit switch switches for the wrong direction of motion or is switched simultaneously with
the prelimit switch in the opposite direction.
Error type:
Alarm
Remedy:
Exchange forward and backward limit switch signals
E25 (Bit -/-) Upper limit switch switches incorrectly, hoist
The limit switch switches for the wrong direction of motion or is switched simultaneously with
the prelimit switch in the opposite direction.
Error type:
Alarm
Remedy:
Exchange upper and lower limit switch signals
E26 (Bit -/-) Backward limit switch switches incorrectly, trolley
The limit switch switches for the wrong direction of motion or is switched simultaneously with
the prelimit switch in the opposite direction.
Error type:
Alarm
Remedy:
Exchange forward and backward limit switch signals
E27 (Bit -/-) Lower limit switch switches incorrectly, hoist
The limit switch switches for the wrong direction of motion or is switched simultaneously with
the prelimit switch in the opposite direction.
Error type:
Alarm
Remedy:
Exchange upper and lower limit switch signals
E28 – E29 reserved
10.5.3.5
Error in semi-automatic mode
E30 (Bit 31) No path found
Semi-automatic mode (SAM) was unable to find a path between the starting position and the
target position:
● For "on-the-fly unloading," the highest point of the calculated travel curve is higher than the
target. Travel in semi-automatic mode will not start.
● Target cannot be reached because there is an obstacle in the way. Travel in semi-automatic
mode starts; the target is placed in front of the obstacle however.
If the target is in a fixed blocked region, no travel of the crane is initiated and E38 is issued.
Error type:
Error
Remedy:
Check starting position and target position as well as blocked regions
Alarm, error, and system messages
10.5 Error messages
SC integrated STS, GSU
380
Operating Instructions, 07/2019, A5E48271265B AA