Limiting the output velocity
Note
Limitations of the output velocity (e.g. in the converter) can result in a following error and
therefore should only be implemented for safety reasons.
9.3.4
Setting the access code
The access code determines which parameters are displayed with keys "1" to "17" in the
SIMOCRANE CeCOMM parameter menu and which parameters can be edited with the "C"
(Change parameters) command.
The access code can be set with parameter P100.
The following settings are possible:
Access code 0
Crane operator, maintenance personnel
Access code 1
Commissioning engineer
Access code 2
Service technicians and specially trained commissioning personnel
Access code 3
Development engineer
The message "No authorization!" appears when an attempt is made to change a parameter that
does not correspond to the access code.
Parameter P100 (= access code) should be set to 2 for the commissioning.
9.3.5
Setting the language
The language of the diagnostic program is set from the menu "Options/Language" and saved
under parameter P110. German and English are available.
Alternatively, the language parameter P110 can be changed via the Parameters menu. The
appropriate language file is then automatically opened and read. The screen displays are
refreshed, although only the function region in the newly selected language is shown.
Commissioning AddOn Software
9.3 Commissioning requirements for AddOn software
SC integrated STS, GSU
Operating Instructions, 07/2019, A5E48271265B AA