For more information about residual risks of the components in a drive system, see the relevant
sections in the technical user documentation.
1.2
Specific safety information for SIMOTION D4x5
WARNING
Danger to life from hazardous voltage when connecting an unsuitable power supply
Only safety extra low voltage in accordance with EN/IEC 60950-1 may be connected at all
connectors and terminals.
WARNING
Danger to life from unexpected movement of machines on automatic restart
An automatic restart can be programmed for SIMOTION controllers. When the power returns,
the axes start automatically.
Make sure this presents no hazard to personnel or property.
NOTICE
Damage to option boards caused by electric fields or electrostatic discharge
Option boards are ESD-sensitive components.
De-energize the SIMOTION D4x5 device before inserting or removing the option board.
SIMOTION D4x5 is in a de-energized state when all the LEDs are OFF.
Comply with the ESD rules.
NOTICE
Damage to the CompactFlash card from electrical fields or electrostatic discharge
The CompactFlash card is an ESD-sensitive component.
De-energize the SIMOTION D4x5 device before inserting or removing the CompactFlash
card. SIMOTION D4x5 is in a de-energized state when all the LEDs are OFF.
Comply with the ESD rules.
NOTICE
Higher operating temperature if ventilation clearances are too small
The 80 mm clearances above and below the components must be observed.
The unit protects itself from overheating by shutting down.
The ventilation clearance is measured from the lower edge of the module, i.e. the fan/battery
module is not included in the dimension.
Safety instructions
1.2 Specific safety information for SIMOTION D4x5
SIMOTION D4x5
18
Manual, 04/2014