Measures and intervals
Operating situations and characteristics can vary widely. For this reason, only general
maintenance intervals are specified here. Maintenance intervals should therefore be
scheduled to suit the local conditions, such as dirt, number starting operations, load, etc.
Measures
Operating period interval
Intervals
Initial inspection
After 500 operating hours
After 1/2 year at the latest
Regreasing
See the lubricant plate
Clean
Depending on the degree of pollution
Main inspection
Approximately every 16000 operating
hours
After 2 years at the latest
Drain condensate
Depending on the climatic conditions
9.2.6
Servicing and maintaining the anti-condensation heating
The anti-condensation heating is maintenance-free. If it is defective, then contact
the Service Center (Page 153).
9.2.7
Servicing the external fan
WARNING
Injury caused by rotating parts or live (under voltage) parts
Live electrical parts are dangerous. Contact with them can cause death, serious injury or
material damage.
● Before carrying out any maintenance work on the external fan, disconnect it from the
mains, particularly before opening the terminal box.
● Make sure that the device cannot be switched back on.
Servicing the external fan
However, dirt and dust deposits on the impeller and the motor, particularly in the gap between
the impeller and the inlet nozzle can impair its function.
● Remove the dirt and dust deposits regularly; the intervals depend on how dirty the
surrounding area is.
● Make sure that the impeller is cleaned evenly, as irregular deposits can lead to an
imbalance.
● The full air flow can only be achieved when air can freely flow through the impeller.
● There must be a clearance of at least 1 x air intake diameter in the axial direction.
● A uniform gap must be maintained between the impeller and the air intake assembly.
Maintenance
9.2 Inspection and maintenance
1MB5 SH 400/450
110
Operating Instructions, 05/2019, A5E45959221A
Содержание SIMOTICS XP 1MB5 SH400
Страница 2: ......
Страница 10: ...Table of contents 1MB5 SH 400 450 8 Operating Instructions 05 2019 A5E45959221A ...
Страница 64: ...Assembly 5 4 Aligning and fixing the machine 1MB5 SH 400 450 62 Operating Instructions 05 2019 A5E45959221A ...
Страница 106: ...Operation 8 8 Non operational periods 1MB5 SH 400 450 104 Operating Instructions 05 2019 A5E45959221A ...
Страница 154: ...Disposal 11 5 Disposal of components 1MB5 SH 400 450 152 Operating Instructions 05 2019 A5E45959221A ...
Страница 156: ...Service support 1MB5 SH 400 450 154 Operating Instructions 05 2019 A5E45959221A ...
Страница 160: ...Quality documents 1MB5 SH 400 450 158 Operating Instructions 05 2019 A5E45959221A ...
Страница 165: ......
Страница 166: ...Germany More information www siemens com drives Siemens AG Digital Industries Postfach 48 48 90026 NÜRNBERG ...