WARNING
Explosion hazard due to excessively high temperatures
If the anti-condensation heating is switched on directly after the machine is switched off, the
temperature class or the maximum surface temperature of the machine can be exceeded.
In an explosive atmosphere, there is a risk of an explosion. This can result in death, serious
injury or material damage.
● Only switch on the anti-condensation heating at the earliest two hours after the machine
has been switched off.
8.8
Non-operational periods
The stoppage is a shutdown for a period of time, during which the machine is stopped but
remains at the location of use.
Under normal ambient conditions, e.g. the stationary machine is not exposed to any vibration,
no increased level of corrosion, ... then the following measures are required.
8.8.1
Measures in non-operational periods
Longer non-operational periods
● For longer non-operational periods (> 1 month), either operate the machine or at least turn
the rotor regularly, approximately once per month.
● If attached, remove the rotor shipping brace before you turn the rotor.
● Please refer to the section "Switching on" before switching on to recommission the motor.
NOTICE
Restricted motor function
If not used for longer periods of time, material damage or complete motor failure can occur.
If the motor is out of service for a period of more than 12 months, then environmental effects
can damage the motor.
● Apply suitable corrosion protection, preservation, packing and drying measures.
Switching on the anti-condensation heating, if available
Switch on the anti-condensation heating two hours after the machine has been switched off.
Operation
8.8 Non-operational periods
1MB5 SH 400/450
102
Operating Instructions, 05/2019, A5E45959221A
Содержание SIMOTICS XP 1MB5 SH400
Страница 2: ......
Страница 10: ...Table of contents 1MB5 SH 400 450 8 Operating Instructions 05 2019 A5E45959221A ...
Страница 64: ...Assembly 5 4 Aligning and fixing the machine 1MB5 SH 400 450 62 Operating Instructions 05 2019 A5E45959221A ...
Страница 106: ...Operation 8 8 Non operational periods 1MB5 SH 400 450 104 Operating Instructions 05 2019 A5E45959221A ...
Страница 154: ...Disposal 11 5 Disposal of components 1MB5 SH 400 450 152 Operating Instructions 05 2019 A5E45959221A ...
Страница 156: ...Service support 1MB5 SH 400 450 154 Operating Instructions 05 2019 A5E45959221A ...
Страница 160: ...Quality documents 1MB5 SH 400 450 158 Operating Instructions 05 2019 A5E45959221A ...
Страница 165: ......
Страница 166: ...Germany More information www siemens com drives Siemens AG Digital Industries Postfach 48 48 90026 NÜRNBERG ...