![Siemens SIMOTICS-T 1FW6 Series Скачать руководство пользователя страница 98](http://html.mh-extra.com/html/siemens/simotics-t-1fw6-series/simotics-t-1fw6-series_operating-instructions-manual_379084098.webp)
Decommissioning and disposal
9.2 Disposal
Naturally cooled 1FW6 built-in torque motors
98
Operating Instructions, 07/2017, 6SN1197-0AF02-0BP2
8.
Separate the flange surface of the stator from the machine enclosure – and the flange
surface of the rotor from the moving axis. The removed rotor must always be carefully
moved, as the transport locks are only at one end.
9.
Only screw the transport locks to the still unprotected flange face of the motor.
10.Pack the motor in the original packaging and store it correctly.
9.2
Disposal
The product must be disposed of in the normal recycling process in compliance with national
and local regulations.
WARNING
Injury or material damage if not correctly disposed of
If you do not correctly dispose of direct drives or their components (especially components
with permanent magnets), then this can result in death, severe injury and/or material
damage.
•
Ensure that direct drives and their associated components are correctly disposed of.
Main constituents of a proper disposal procedure
●
Complete demagnetization of the components that contain permanent magnets
●
Components that are to be recycled should be separated into:
–
Electronics scrap (e.g. encoder electronics, Sensor Modules)
–
Electrical scrap (e.g. motor windings, cables)
–
Scrap iron (e.g. laminated cores)
–
Aluminum
–
Insulating materials
●
No mixing with solvents, cold cleaning agents, or residue of paint, for example