5.3
Installing the converter
5.3.1
Installation conditions
When installing the converter carefully observe the conditions listed below in order to
guarantee reliable, continuous and trouble-free operation.
● The converter is designed for installation in a control cabinet.
● The converter is certified for use in environments with degree of pollution 2 without
condensation; i.e. in environments where no conductive pollution/dirt occurs. Condensation
is not permissible.
● The converter fulfills degree of protection IP20.
● EMC-compliant installation:
EMC-compliant installation of a machine or system (Page 35).
Additional requirements for plants and systems in the United States / Canada (UL/cUL)
A label with the following number is provided with the device: A5E36790112.
Note the instructions on the label and attach the label in a clearly visible location close to the
converter in the control cabinet.
Installation notes
● Install the converter vertically with the flap for the LED display facing upwards.
Figure 5-2
Mounting position of the converter
● Maintain the minimum clearances to other components.
● Use the recommended hardware (screws M5) and comply with the specified torques.
Installing
5.3 Installing the converter
SINAMICS S210 servo drive system
Operating Instructions, 12/2017, A5E41702836B AA
87
Содержание SIMOTICS S-1FK2
Страница 2: ......
Страница 12: ...Table of contents SINAMICS S210 servo drive system 10 Operating Instructions 12 2017 A5E41702836B AA ...
Страница 226: ...Ordering data 11 5 Spare parts SINAMICS S210 servo drive system 224 Operating Instructions 12 2017 A5E41702836B AA ...
Страница 292: ...Parameters 12 2 List of parameters SINAMICS S210 servo drive system 290 Operating Instructions 12 2017 A5E41702836B AA ...
Страница 766: ...Index SINAMICS S210 servo drive system 764 Operating Instructions 12 2017 A5E41702836B AA ...
Страница 767: ......