Requirements relating to shielded cables
● Use cables with finely-stranded, braided shields.
● Connect the shield at both ends of the cable.
2&&FRQQHFWLRQFDEOHWRWKH
PRWRU
)HUULWHFRUHUHTXLUHGIRU)6%
IRU(0&&DWHJRU\&
&RQQHFWLRQFDEOHIRUH[WHUQDO
EUDNLQJUHVLVWRU
&RQQHFWLRQFDEOHIRUIDLOVDIHGLJLWDO
LQSXWDQGSUREH
Figure 3-2
Shield support with the shield terminal from the scope of supply of the MOTION-
CONNECT OCC cable.
● Connect the shield to the shield support.
● Do not interrupt the shield.
3.1.3
Electromechanical components
Surge voltage protection circuit
● Connect surge voltage protection circuits to the following components:
– Coils of contactors
– Relays
– Solenoid valves
● Connect the surge voltage protection circuit directly at the coil.
● Use RC elements or varistors for AC-operated coils and freewheeling diodes or varistors
for DC-operated coils.
Configuring
3.1 EMC-compliant installation of a machine or system
SINAMICS S210 servo drive system
38
Operating Instructions, 12/2017, A5E41702836B AA
Содержание SIMOTICS S-1FK2
Страница 2: ......
Страница 12: ...Table of contents SINAMICS S210 servo drive system 10 Operating Instructions 12 2017 A5E41702836B AA ...
Страница 226: ...Ordering data 11 5 Spare parts SINAMICS S210 servo drive system 224 Operating Instructions 12 2017 A5E41702836B AA ...
Страница 292: ...Parameters 12 2 List of parameters SINAMICS S210 servo drive system 290 Operating Instructions 12 2017 A5E41702836B AA ...
Страница 766: ...Index SINAMICS S210 servo drive system 764 Operating Instructions 12 2017 A5E41702836B AA ...
Страница 767: ......